raisecomPowerDeviceInputType
RAISECOM-PON-DEVICE-MIB ·
.1.3.6.1.4.1.8886.1.27.4.1.1.2
Object
column
Enumeration
Input type of this power device. Null value means that this power device is plugged out.
Context
- MIB
- RAISECOM-PON-DEVICE-MIB
- OID
.1.3.6.1.4.1.8886.1.27.4.1.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- raisecomPowerDeviceEntry
- Table
- raisecomPowerDeviceTable
- Siblings
- 10
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | unknown |
2 | ac |
3 | dc48 |
4 | dc24 |
5 | dc12 |
6 | null |
7 | ac220 |
8 | ac110 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| raisecomPowerDeviceIndex Power device id. | column | RAISECOM-PONSERIES-TCSlotIndex | .1.3.6.1.4.1.8886.1.27.4.1.1.1 |
| raisecomPowerInputvolalarmState The input voltage alarm state of the power device, it is only meaningful for the manageable power. | column | Enumeration | .1.3.6.1.4.1.8886.1.27.4.1.1.10 |
| raisecomPowerInputvolMinlowerVolThres The input voltage lower threshold of the Minor alarm , it is only meaningful for the manageable power. | column | Integer32 | .1.3.6.1.4.1.8886.1.27.4.1.1.11 |
| raisecomPowerInputvolMajlowerVolThres The input voltage lower threshold of the Major alarm,
it is only meaningful for the manageable power . | column | Integer32 | .1.3.6.1.4.1.8886.1.27.4.1.1.12 |
| raisecomPowerInputvolCrilowerVolThres The input voltage lower threshold of the Critical alarm ,
it is only meaningful for the manageable power. | column | Integer32 | .1.3.6.1.4.1.8886.1.27.4.1.1.13 |
| raisecomPowerInputvolMinupperVolThres The input voltage upper threshold of the Minor alarm ,
it is only meaningful for the manageable power. | column | Integer32 | .1.3.6.1.4.1.8886.1.27.4.1.1.14 |
| raisecomPowerInputvolMajupperVolThres The input voltage upper threshold of the Major alarm ,
it is only meaningful for the manageable power. | column | Integer32 | .1.3.6.1.4.1.8886.1.27.4.1.1.15 |
| raisecomPowerInputvolCriupperVolThres The input voltage upper threshold of the Critical alarm ,
it is only meaningful for the manageable power. | column | Integer32 | .1.3.6.1.4.1.8886.1.27.4.1.1.16 |
| raisecomPowerTemperatureThres The temperature threshold of the power device ,
it is only meaningful for the manageable power, not used in V2.0. | column | Integer32 | .1.3.6.1.4.1.8886.1.27.4.1.1.17 |
| raisecomPowerInputvol The input voltage of this power device, it is only meaningful for the manageable power. | column | Integer32 | .1.3.6.1.4.1.8886.1.27.4.1.1.9 |