rndMonitoredObjectInstanceLabel
RADWARE-MIB ·
.1.3.6.1.4.1.89.35.2.4.1.2
Object
column
mandatory
OctetString
The label assigned by the network manager to the monitored object instance
Context
- MIB
- RADWARE-MIB
- OID
.1.3.6.1.4.1.89.35.2.4.1.2- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- rndMonitoringEntry
- Table
- rndMonitoringTable
- Siblings
- 10
Syntax
OctetString
Values & Constraints
Object Constraints
range: 1-20
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rndMonitoredElement mandatory A label assigned by the network manager to a monitored element to
which this monitored object instance belongs. This label must have
been previously entered in an instance of rndM… | column | OctetString | .1.3.6.1.4.1.89.35.2.4.1.1 |
| rndMonitoringLogfile mandatory The entire path of the file in which the results of the monitoring
of this object instance should be recorded. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.89.35.2.4.1.10 |
| rndMonitoringEntryStatus mandatory It is used to manage the monitored object instances table and
indicates the current monitoring status of an object instance. | column | RowStatus | .1.3.6.1.4.1.89.35.2.4.1.11 |
| rndMonitoredObjectName mandatory The symbolic object type name of the object to which the monitored object
instance belongs (as it appears the MIB module definition). In case of
ambiguity the <MIB module name> : … | column | OctetString | .1.3.6.1.4.1.89.35.2.4.1.3 |
| rndMonitoredObjectIdentifier mandatory The object identifier of the object to which the monitored object
instance belongs.
An instance of rndMonitoredObjectIdentifier need not be assigned any value, if
the correspondin… | column | ObjectIdentifier | .1.3.6.1.4.1.89.35.2.4.1.4 |
| rndMonitoredObjectInstance mandatory The instance identifier (key) of the monitored object instance. | column | ObjectIdentifier | .1.3.6.1.4.1.89.35.2.4.1.5 |
| rndMonitoredObjectSyntax mandatory The syntax of the monitored object instance (i.e., the syntax of the object
type of the object to which the monitored instance belongs).
Need not be assigned any value if the corr… | column | Enumeration | .1.3.6.1.4.1.89.35.2.4.1.6 |
| rndMonitoringInterval mandatory The period of time between two consecutive retrievals of the monitored
object instance's value. | column | Integer32 | .1.3.6.1.4.1.89.35.2.4.1.7 |
| rndAlarmMaxTreshold mandatory The value of the monitored object instance, the exceeding of which
will cause the generation of an alarm to the high-level management
station. | column | Integer32 | .1.3.6.1.4.1.89.35.2.4.1.8 |
| rndAlarmMinTreshold mandatory If the value of the monitored object instance falls below the value
assigned to rndAlarmMinTreshold, an alarm to the high-level management
station will be issued. | column | Integer32 | .1.3.6.1.4.1.89.35.2.4.1.9 |