prtInPh1MlMaxIdleTime

RAD-Mpmx-MIB · .1.3.6.1.4.1.164.3.2.3.2.2.3.1.18

Object

column r/w Integer32
Move to higher prioritized connected link	after this period of
seconds of silence on the current link.
	  0=Never. Never move to higher prioritized connected link.
UNIT is seconds.
Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300,
360, 420, 480, 540, 600, 900, 1200, 1500, 1800.
Attempt to Set an invalid value will result in getting the default value.

Context

MIB
RAD-Mpmx-MIB
OID
.1.3.6.1.4.1.164.3.2.3.2.2.3.1.18
Type
column
Access
readwrite
Status
current
Parent
prtInPh1MlCnfgEntry
Table
prtInPh1MlCnfgTable
Siblings
23

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-1800