agnCnfgAlrSlot
RAD-Mpmx-MIB ·
.1.3.6.1.4.1.164.3.1.2.2.8.2.1.2
Object
column
Enumeration
The alarm slot. The following attributes apply for the alarm code and slot selected. all = the attributes apply to all slots. notApplicable = the selected alarm is for system level. For the Vmux2100 Main Board clA (3) is used.
Context
- MIB
- RAD-Mpmx-MIB
- OID
.1.3.6.1.4.1.164.3.1.2.2.8.2.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- agnCnfgAlrEntry
- Table
- agnCnfgAlrTable
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | psA |
2 | psB |
3 | clA |
4 | clB |
5 | io1 |
6 | io2 |
7 | io3 |
8 | io4 |
9 | io5 |
10 | io6 |
11 | io7 |
12 | io8 |
13 | io9 |
14 | io10 |
15 | io11 |
16 | io12 |
17 | io13 |
18 | io14 |
19 | io15 |
200 | all |
255 | notApplicable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| agnCnfgAlrCode The alarm code. The following attributes refer this code. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.1.2.2.8.2.1.1 |
| agnCnfgAlrPort The alarm port. The following attributes apply for the alarm
code,slot and port selected.
200 = all = the attributes apply to all ports of the selected slot.
When selected S… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.1.2.2.8.2.1.3 |
| agnCnfgAlrMask An attribute defining the desired Mask state of an alarm .
no - unmask (this command is not saved in agent's common
database)
noAndSave - unmask ; this command is saved in a… | column | Enumeration | .1.3.6.1.4.1.164.3.1.2.2.8.2.1.4 |
| agnCnfgAlrInvert An attribute defining the desired Invert state of an alarm .
no - not inverted.
yes - inverted. For MP, it is not applicable for alarms
that are currently OFF. | column | Enumeration | .1.3.6.1.4.1.164.3.1.2.2.8.2.1.5 |
| agnCnfgAlrFilter An attribute defining if Filter is desired for the alarm .
no - no filter.
yes - filter activate.
This filter is activated within a window of time defined by
agnC… | column | Enumeration | .1.3.6.1.4.1.164.3.1.2.2.8.2.1.6 |
| agnCnfgAlrFilterSet This is a top threshold causing the alarm that passes it,
to be declared Set (ON) at the end of the respective
window of time.
- For alarms defined by default as state alarms (min… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.1.2.2.8.2.1.7 |
| agnCnfgAlrFilterReset This is a bottom threshold causing the alarm that does not
pass it, to be declared Reset (ON) at the end of the
respective window of time.
- For alarms defined by default as state… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.1.2.2.8.2.1.8 |
| agnCnfgAlrSeverity An attribute defining desired severity of an alarm code
per slot/port | column | Enumeration | .1.3.6.1.4.1.164.3.1.2.2.8.2.1.9 |