pktcSigServiceClassNameUS

PKTC-SIG-MIB · .1.3.6.1.4.1.4491.2.2.2.1.1.13

Object

scalar obsolete r/w OctetString
This object contains a string indicating the Service 
Class name to create an Upstream Service (US) Flow for 
NCS. If the object has an empty string value then the 
upstream NCS SF is not created and the best effort 
SF is used for upstream NCS data. The creation of the NCS 
SF primary occurs before Voice Communication Service is 
activated on the device. If this object is set to a 
non-empty (non-zero length) string, the MTA MUST create 
the NCS SF if it does not currently exist and the 
pktcSigServiceClassNameMask object has a non-zero value. 
If this object is subsequently set to an empty 
(zero-length)string , the MTA MUST delete the NCS SF 
if it exists.  Setting this object to a different value 
does not cause the Upstream Service Flow to be 
re-created. The string MUST contain printable ASCII
characters. The length of the string does not include a 
terminating zero.  The MTA MUST append a terminating zero
when the MTA creates the service flow.

Context

MIB
PKTC-SIG-MIB
OID
.1.3.6.1.4.1.4491.2.2.2.1.1.13
Type
scalar
Access
readwrite
Status
obsolete
Parent
pktcSigDevConfigObjects
Siblings
23

Syntax

OctetString

Values & Constraints

Object Constraints
range: 0-15