mcrModuleModelDesc
PERLE-MCR-MGT-MIB ·
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.19
Object
column
SNMPv2-TCDisplayString
This object identifies a static description of the media converter module present in the slot.
Context
- MIB
- PERLE-MCR-MGT-MIB
- OID
.1.3.6.1.4.1.1966.21.1.1.1.1.3.1.19- Type
- column
- Access
- readonly
- Status
- current
- Parent
- mcrChassisSlotEntry
- Table
- mcrChassisSlotTable
- Siblings
- 17
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| mcrModuleDiagStatus This object identifies the module's self-test diagnostics result. It will
return zero if it passed and non-zero error code if the module has
failed.The following are possible non-… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.10 |
| mcrModuleTypeInserted This object identifies the module type inserted for this chassis slot. | column | Enumeration | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.11 |
| mcrMediaConfigBackupRestore This object is applicable to media converter modules only. It identifies
whether the media configuration will be automatically backed up to
or restored from the management card's … | column | Enumeration | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.12 |
| mcrMediaBackedupModuleType This object identifies the media converter module type of the configuration that
was backed up for the slot on the management card's non-volatile
memory when the mcrMediaConfigBac… | column | Enumeration | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.13 |
| mcrChassisPwrUpSlotPwrState This object identifies the default power state of the slot when the
chassis is initially powered up. The current power state of the slot
can be manually changed by writing to mcr… | column | OnOffValue | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.14 |
| mcrCurrentPowerState Writing this object allows the current power state of the slot to be
turned on or off. This object is not writable for management modules
or the 2-slot chassis.
Reading this objec… | column | OnOffValue | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.15 |
| mcrPowerScheduleEnable This object is not applicable to management modules. It identifies
if power schedule is enabled for the slot.
(Not applicable to 2-slot chassis.) | column | Enumeration | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.16 |
| mcrModuleReset This object allows you to reset the module inserted in the slot. | column | Enumeration | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.17 |
| mcrModuleResetToFactory This object allows you to reset to factory the module inserted in
the slot. | column | Enumeration | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.18 |
| mcrChassisSlotIndex This object identifies the chassis slot number. | column | SlotNumber | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.2 |
| mcrUserDefinedModuleName This object identifies the user defined name of the module inserted
in the slot. The default name is the model name of the media converter module | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.3 |
| mcrModuleModelName This object identifies the model name of the module inserted
in the slot. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.4 |
| mcrUnManagedModuleSlotName This object identifies the user defined name for an unmanaged
module inserted in the slot. Unmanaged modules include all perle
C-1000, C-100, C-1110 and c-110 type modules. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.5 |
| mcrModuleSerialNumber This object identifies the serial number of the module inserted
in the slot. | column | OctetString | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.6 |
| mcrModuleBootloaderVersion This object identifies the bootloader version of the module inserted
in the slot. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.7 |
| mcrModuleFirmwareVersion This object identifies the firmware version of the module inserted
in the slot. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.8 |
| mcrModuleoOutStandWarnAlarms This object identifies the number of outstanding warnings and alarms for
this module. If this value is not zero then user intervention is needed
to resolve the outstanding warning… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.1966.21.1.1.1.1.3.1.9 |