osSoamDmCfgMeasBinTable

OS-PROV-SOAM-PM-MIB · .1.3.6.1.4.1.6926.2.10.33.1.4.2

Object

table
This table includes configuration attributes for the Delay Measurement 
bins to collect stats.
          
Each row in the table is automatically created when the Delay
Measurement session is defined for the selected Flow. The number of rows
created is based upon three items: the DM type, the number of bins
defined for each type, and whether bins are enabled for each type.
          
The first four indices are the same as used to create the DM session:
Maintenance Domain, MaNet, Flow identification, and osSoamDmCfgIndex. The
fifth index is the type of bin, and the sixth index is the bin number.
          
For a dmDmm session all six types of bins can be created. For a dm1DmmTx
session no bins are created. For a dm1DmmRx session only types 
FwFd and FwIfdv can be created.
          
The number of bins created for a bin type is based upon: the 
osSoamPmDmPrflNuMeasBinPrFdInt object, the 
osSoamPmDmPrflNuMeasBinPrIfdvInt object, and
the osSoamPmDmPrflMeasurementEnable object.
          
For instance, if a dmDmm session with Bins per Frame Delay Int 
set to 5, Bins per Frame Delay Variation Int set to 3, and all 
of the appropriate bits set in osSoamDmMeasurementCfgEnable, the 
following number of rows would be created:
          
For bin types TwFd(1), FwFd(2), and 
BwFd(3) = 5 bins * 3 types = 15 rows
          
For bin types TwIfdv(4), FwIfdv(5), BwIfdv(6) = 
3 bins * 3 types = 9 rows.         
          
This gives a total of 24 rows created for the DMM session example.
          
Each value in the bin defaults to 5000us greater than the previous bin,
with the first bin default value set to 0.
          
For the delay example above (5 bins), the following default values 
would be written to the bins:
      bin 1:     0  (range is 0us <= measurement < 5,000us)
      bin 2:  5000  (range is 5,000us <= measurement < 10,000us)
      bin 3: 10000  (range is 10,000us <= measurement < 15,000us)
      bin 4: 15000  (range is 15,000us <= measurement < 20,000us)
      bin 5: 20000  (range is 20,000us <= measurement < infinity)
          
For the delay variation example above (3 bins), the following default 
values would be written to the bins:
      bin 1:     0  (range is 0us <= measurement < 5,000us)
      bin 2:  5000  (range is 5,000us <= measurement < 10,000us)
      bin 3: 10000  (range is 10,000us <= measurement < infinity)
          
The writable objects in this table need to be persistent upon reboot 
or restart of a device. 
          
Rows are only created if the corresponding measurement type has been enabled 
via the osSoamPmDmPrflMeasurementEnable object.

Context

MIB
OS-PROV-SOAM-PM-MIB
OID
.1.3.6.1.4.1.6926.2.10.33.1.4.2
Type
table
Status
current
Parent
osSoamPmDmObjects
Siblings
5
Children
1

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects
Child Objects