optixRtnNonCascade1j1PGSwitchTrap
OPTIX-RTN-IF-PROTECT-MGR-MIB ·
.1.3.6.1.4.1.2011.2.25.4.40.5.30.41
Object
notification
Indicates a none-cascading IF 1+1 protection group switching event.
Context
- MIB
- OPTIX-RTN-IF-PROTECT-MGR-MIB
- OID
.1.3.6.1.4.1.2011.2.25.4.40.5.30.41- Type
- notification
- Status
- current
- Parent
- optixRtnTrap
- Siblings
- 15
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| optixRtnIF1j1PGSwitchTrap Indicates an IF 1+1 protection group switching event. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.10 |
| optixRtnIFPhyAggMemberPriSwitchTrapExt Indicates the member priority switching event of a PLA group | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.100 |
| optixRtnIFNj1PGSwitchTrap Indicates an IF N+1 protection group switching event. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.20 |
| optixRtnIFNj1PGFarNoResponseTrap Indicates an IF N+1 protection group no far-end response event. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.21 |
| optixRtnIFPhyLagPGScheduleModeChangeTrap Indicates an IF PLA group schedule mode change event. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.240 |
| optixRtnIFPhyLagPGSwitchTrap Indicates an IF PLA group switching event. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.30 |
| optixRtnIFCascading1j1PGSwitchTrap Indicates a cascading IF 1+1 protection group switching event. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.40 |
| optixRtnIFBitErrorCodeTestTrap Indicates IF bit errors. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.43 |
| optixRtnIFBitOldTestTrap Indicates IF bit errors. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.46 |
| optixRtnIFBitTestTrap Indicates IF bit errors. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.47 |
| optixRtnIFBitErrorCodeExTestTrap Indicates IF bit errors. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.48 |
| optixRtnE1PRBSTestTrap Indicates result of the E1prbs extension interface. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.49 |
| optixRtnIFCascadingPhyLagPGSwitchTrap Indicates a cascading PLA group switching event. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.50 |
| optixRtnIFCascadingPhyLagPGSwitchTrapExt Indicates a cascading PLA group switching event. | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.60 |
| optixRtnIFPhyAggMemberStateSwitchTrapExt Indicates the member state switching event of a PLA group | notification | - | .1.3.6.1.4.1.2011.2.25.4.40.5.30.90 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| optixRtnNonCascade1J1GPID Indicates the protection group ID. | scalar | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.2.25.4.40.5.20.41.1 |
| optixRtnNonCascade1J1BoardID Indicates the slot ID of the current working board on the equipment side. | scalar | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.2.25.4.40.5.20.41.2 |
| optixRtnNonCascade1J1SubCardID Indicates the subcard ID of the current working board on the equipment side. | scalar | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.2.25.4.40.5.20.41.3 |
| optixRtnNonCascade1J1PortID Indicates the port ID of the current working board on the equipment side. | scalar | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.2.25.4.40.5.20.41.4 |
| optixRtnNonCascade1J1DevWorkBoardProperty Indicates whether the current working board on the equipment board is a working or protection board. The values are as follows:
0-working
1-protection | scalar | OPTIXRtn1j1DevWorkBoardProperty | .1.3.6.1.4.1.2011.2.25.4.40.5.20.41.5 |
| optixRtnNonCascade1J1WorkBoardDevState Indicates the status of the current working board on the equipment side. The values are as follows:
0-normal
1-fail
2-rdi
255-unknown | scalar | OPTIXRtn1j1PGBDStateType | .1.3.6.1.4.1.2011.2.25.4.40.5.20.41.6 |
| optixRtnNonCascade1J1ProtBoardDevState Indicates the status of the current protection board on the equipment side. The values are as follows:
0-normal
1-fail
2-rdi
255-unknown | scalar | OPTIXRtn1j1PGBDStateType | .1.3.6.1.4.1.2011.2.25.4.40.5.20.41.7 |
| optixRtnNonCascade1J1DevSwtichRequest Indicates the equipment-side switching request:
0-state-normal
1-state-auto
2-state-manual
3-state-force
4-state-lockout
5-state-wtr