per24hMonitorEndTime
OPTIX-GLOBAL-PER-TIME-MIB ·
.1.3.6.1.4.1.2011.2.25.3.40.20.10.20.20
Object
Indicates the end date and time of the 24-hour PM period. The end date and time of the 24-hour PM period must be set after the start date and time of the 24-hour PM period is set. And the end date and time of the 24-hour PM period must be later than the start date and time of the 24-hour PM period. When the end date and time of the 24-hour PM period is set to 1990-00-00 00:00:00, it indicates immediate end of the 24-hour PM period monitoring. When the 24-hour PM period expires, the end date and time of the 24-hour PM period will be reset to zero.
Context
- MIB
- OPTIX-GLOBAL-PER-TIME-MIB
- OID
.1.3.6.1.4.1.2011.2.25.3.40.20.10.20.20- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- per24hMonitorTime
- Siblings
- 1
Values & Constraints
Type Constraints
range: 8
range: 11
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| per24hMonitorStartTime Indicates the start date and time of the 24-hour PM period. When the system is at this time, the 24-hour PM period monitoring starts. The start date and time of the 24-hour PM per… | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.2011.2.25.3.40.20.10.20.10 |