per15mMonitorEndTime
OPTIX-GLOBAL-PER-TIME-MIB ·
.1.3.6.1.4.1.2011.2.25.3.40.20.10.10.20
Object
Indicates the end time and date of the 15-minute PM period. The end date and time of the 15-minute PM period must be set after the start date and time of the 15-minute PM period is set. And the end date and time of the 15-minute PM period must be later than the start date and time of the 15-minute PM period. When the end date and time of the 15-minute PM period is set to 1990-00-00 00:00:00, it indicates immediate end of the 15-minute PM period monitoring. When the 15-minute PM period expires, the end date and time of the 15-minute PM period will be reset to zero.
Context
- MIB
- OPTIX-GLOBAL-PER-TIME-MIB
- OID
.1.3.6.1.4.1.2011.2.25.3.40.20.10.10.20- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- per15mMonitorTime
- Siblings
- 1
Values & Constraints
Type Constraints
range: 8
range: 11
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| per15mMonitorStartTime Indicates the start time and date of the 15-minute PM period. When the system is at this time, the 15-minute PM period monitoring starts. The start date and time of the 15-minute … | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.2011.2.25.3.40.20.10.10.10 |