ons15501SysDevActiveImage
ONS15501-MIB ·
.1.3.6.1.4.1.1869.11.11.1.5
Object
scalar
Unsigned32
Show currently active image's bank number. This may be different from ons15501SysConfiguredActiveImage, if a. The image on ons15501SysConfiguredActiveImage did not boot properly. b. User chose another bank during bootup, using the serial console port.
Context
- MIB
- ONS15501-MIB
- OID
.1.3.6.1.4.1.1869.11.11.1.5- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- ons15501Sys
- Siblings
- 24
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-3
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ons15501SysDevFlash1Image Gives the name of the software programmed on flash
bank one. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.1 |
| ons15501PrimaryNTP The IP address for the primary NTP server. | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.1869.11.11.1.10 |
| ons15501SecondaryNTP The IP address for the secondary NTP server. | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.1869.11.11.1.11 |
| ons15501NTPAdminStatus The configured administrative status for NTP. | scalar | Ons15501AdminStatus | .1.3.6.1.4.1.1869.11.11.1.12 |
| ons15501NTPOperationalStatus The operational status for NTP. | scalar | Ons15501NTPStatus | .1.3.6.1.4.1.1869.11.11.1.13 |
| ons15501ActiveSoftwareVer This attribute provides the active software version.
This will be same as the entPhysicalSoftwareRev for
the entry corresponding to the chassis. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.14 |
| ons15501LastConfigChangeTime The value of sysUpTime when last configuration
change was done.
NMS may use this information to synchronize if
some configuration has changed on the unit. | scalar | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.1869.11.11.1.15 |
| ons15501InRemoteInfoUpdateTime This attribute gives the time-stamp when one or more of
ons15501InRemoteChassisName, ons15501InRemotePortName,
or ons15501InRemoteAgentIpAddr was changed.
NMS may use this informa… | scalar | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.1869.11.11.1.16 |
| ons15501InRemoteChassisName Manager initialized string value to identify the
chassis associated with remote connection for
optical input.
ons15501InRemoteChassisName would be a ZERO length
string if the inpu… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.17 |
| ons15501InRemotePortName Manager initialized string value to identify the
the port (on remote chassis) associated with remote
connection for optical input.
ons15501InRemotePortName would be a ZERO length
… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.18 |
| ons15501InRemoteAgentIpAddr Manager initialized string value to identify the
network address to be used to reach the SNMP agent
entity containing information about the port and chassis
providing optical inpu… | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.1869.11.11.1.19 |
| ons15501SysDevFlash2Image Gives the name of the software programmed on flash
bank two. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.2 |
| ons15501OutRemoteInfoUpdateTime This attribute gives the time-stamp when one or more of
ons15501OutRemoteChassisName, ons15501OutRemotePortName,
or ons15501OutRemoteAgentIpAddr was changed.
NMS may use this info… | scalar | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.1869.11.11.1.20 |
| ons15501OutRemoteChassisName Manager initialized string value to identify the
chassis associated with remote connection for
optical output.
ons15501OutRemoteChassisName would be a ZERO length
string if the ou… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.21 |
| ons15501OutRemotePortName Manager initialized string value to identify the
the port (on remote chassis) associated with remote
connection for optical output.
ons15501OutRemotePortName would be a ZERO lengt… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.22 |
| ons15501OutRemoteAgentIpAddr Manager initialized string value to identify the
network address to be used to reach the SNMP agent
entity containing information about the port and chassis
using optical output.
… | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.1869.11.11.1.23 |
| ons15501SysAlarmStatus Provides the highest severity alarm currently active. | scalar | Ons15501AlarmStatus | .1.3.6.1.4.1.1869.11.11.1.24 |
| ons15501SysDateAndTime The date and time of the System.
The write will not succeed if the administrative
state for NTP (ons15501NTPAdminStatus)
is 'enabled'.
Setting this attribute will autmatically cha… | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.1869.11.11.1.25 |
| ons15501SysDevFlash3Image Gives the name of the software programmed on flash
bank three. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.3 |
| ons15501SysSwDownload Used to control the image download to the flash banks.
NOTE: Read on this attribute returns the last t/ftp command,
without login/password.
For s/w release 4.0 and abo… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.4 |
| ons15501SysDeviceManagerList A ',' separated list of managers that will receive the
Traps.
If a specific host should receive the traps sent from this
unit, it should be added to the list using CLI.
Up to 16 m… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.6 |
| ons15501SysSwDownloadStatus Denotes the FTP/TFTP status. Please refer to the description
of Ons15501ImageDnLoadStatus for a list of supported values | scalar | Ons15501ImageDnLoadStatus | .1.3.6.1.4.1.1869.11.11.1.7 |
| ons15501SysConfiguredImage Set/Show configured value for flash-bank number to be used
on reboot.
A set on this attribute will result in a reboot of the system.
To restart the system, write back the same val… | scalar | Unsigned32 | .1.3.6.1.4.1.1869.11.11.1.8 |
| ons15501CLEICode This attribute represents the CLEI (Common Language
Equipment Identifier) code for the ONS15501. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.9 |