ons15501SysConfiguredImage
ONS15501-MIB ·
.1.3.6.1.4.1.1869.11.11.1.8
Object
scalar
r/w
Unsigned32
Set/Show configured value for flash-bank number to be used on reboot. A set on this attribute will result in a reboot of the system. To restart the system, write back the same value as the one read from it (or from ons15501SysDevActiveImage).
Context
- MIB
- ONS15501-MIB
- OID
.1.3.6.1.4.1.1869.11.11.1.8- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- ons15501Sys
- Siblings
- 24
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-3
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ons15501SysDevFlash1Image Gives the name of the software programmed on flash
bank one. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.1 |
| ons15501PrimaryNTP The IP address for the primary NTP server. | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.1869.11.11.1.10 |
| ons15501SecondaryNTP The IP address for the secondary NTP server. | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.1869.11.11.1.11 |
| ons15501NTPAdminStatus The configured administrative status for NTP. | scalar | Ons15501AdminStatus | .1.3.6.1.4.1.1869.11.11.1.12 |
| ons15501NTPOperationalStatus The operational status for NTP. | scalar | Ons15501NTPStatus | .1.3.6.1.4.1.1869.11.11.1.13 |
| ons15501ActiveSoftwareVer This attribute provides the active software version.
This will be same as the entPhysicalSoftwareRev for
the entry corresponding to the chassis. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.14 |
| ons15501LastConfigChangeTime The value of sysUpTime when last configuration
change was done.
NMS may use this information to synchronize if
some configuration has changed on the unit. | scalar | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.1869.11.11.1.15 |
| ons15501InRemoteInfoUpdateTime This attribute gives the time-stamp when one or more of
ons15501InRemoteChassisName, ons15501InRemotePortName,
or ons15501InRemoteAgentIpAddr was changed.
NMS may use this informa… | scalar | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.1869.11.11.1.16 |
| ons15501InRemoteChassisName Manager initialized string value to identify the
chassis associated with remote connection for
optical input.
ons15501InRemoteChassisName would be a ZERO length
string if the inpu… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.17 |
| ons15501InRemotePortName Manager initialized string value to identify the
the port (on remote chassis) associated with remote
connection for optical input.
ons15501InRemotePortName would be a ZERO length
… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.18 |
| ons15501InRemoteAgentIpAddr Manager initialized string value to identify the
network address to be used to reach the SNMP agent
entity containing information about the port and chassis
providing optical inpu… | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.1869.11.11.1.19 |
| ons15501SysDevFlash2Image Gives the name of the software programmed on flash
bank two. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.2 |
| ons15501OutRemoteInfoUpdateTime This attribute gives the time-stamp when one or more of
ons15501OutRemoteChassisName, ons15501OutRemotePortName,
or ons15501OutRemoteAgentIpAddr was changed.
NMS may use this info… | scalar | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.1869.11.11.1.20 |
| ons15501OutRemoteChassisName Manager initialized string value to identify the
chassis associated with remote connection for
optical output.
ons15501OutRemoteChassisName would be a ZERO length
string if the ou… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.21 |
| ons15501OutRemotePortName Manager initialized string value to identify the
the port (on remote chassis) associated with remote
connection for optical output.
ons15501OutRemotePortName would be a ZERO lengt… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.22 |
| ons15501OutRemoteAgentIpAddr Manager initialized string value to identify the
network address to be used to reach the SNMP agent
entity containing information about the port and chassis
using optical output.
… | scalar | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.1869.11.11.1.23 |
| ons15501SysAlarmStatus Provides the highest severity alarm currently active. | scalar | Ons15501AlarmStatus | .1.3.6.1.4.1.1869.11.11.1.24 |
| ons15501SysDateAndTime The date and time of the System.
The write will not succeed if the administrative
state for NTP (ons15501NTPAdminStatus)
is 'enabled'.
Setting this attribute will autmatically cha… | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.1869.11.11.1.25 |
| ons15501SysDevFlash3Image Gives the name of the software programmed on flash
bank three. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.3 |
| ons15501SysSwDownload Used to control the image download to the flash banks.
NOTE: Read on this attribute returns the last t/ftp command,
without login/password.
For s/w release 4.0 and abo… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.4 |
| ons15501SysDevActiveImage Show currently active image's bank number.
This may be different from ons15501SysConfiguredActiveImage,
if
a. The image on ons15501SysConfiguredActiveImage did not
boot p… | scalar | Unsigned32 | .1.3.6.1.4.1.1869.11.11.1.5 |
| ons15501SysDeviceManagerList A ',' separated list of managers that will receive the
Traps.
If a specific host should receive the traps sent from this
unit, it should be added to the list using CLI.
Up to 16 m… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.6 |
| ons15501SysSwDownloadStatus Denotes the FTP/TFTP status. Please refer to the description
of Ons15501ImageDnLoadStatus for a list of supported values | scalar | Ons15501ImageDnLoadStatus | .1.3.6.1.4.1.1869.11.11.1.7 |
| ons15501CLEICode This attribute represents the CLEI (Common Language
Equipment Identifier) code for the ONS15501. | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.1869.11.11.1.9 |