ostY1731BucketPeriod
OMNITRON-Y1731-MIB ·
.1.3.6.1.4.1.7342.8.1.1.1.1.2
Object
column
r/w
Unsigned32
Frame Delay histogram collection period, 1 to 60 minutes. Default is 15 minutes.
Context
- MIB
- OMNITRON-Y1731-MIB
- OID
.1.3.6.1.4.1.7342.8.1.1.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ostY1731GlobalEntry
- Table
- ostY1731GlobalTable
- Siblings
- 4
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-60
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ostY1731Enable Enables Y.1731 operation when true, otherwise Y.1731 operation is disabled.
Default value is false(2), disabling Y.1731 operation. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.7342.8.1.1.1.1.1 |
| ostY1731BinLimits A text string list of the Frame Delay histogram bin limits.
The format of the string is as follows:
1 to 15 unsigned integers separated by commas. The values mu… | column | OctetString | .1.3.6.1.4.1.7342.8.1.1.1.1.3 |
| ostY1731VarBinLimits A text string list of the Frame Variable Delay histogram bin limits.
The format of the string is as follows:
1 to 15 unsigned integers separated by commas. The … | column | OctetString | .1.3.6.1.4.1.7342.8.1.1.1.1.4 |
| ostY1731ProbeDlyUnits This object selects the delay value units that are in the delay results tables.
ms(1) Delay values are in milliseconds
us(2) Delay values are in micro… | column | Enumeration | .1.3.6.1.4.1.7342.8.1.1.1.1.5 |