envPresent
OLD-CISCO-ENV-MIB ·
.1.3.6.1.4.1.9.2.1.77
Object
scalar
mandatory
Integer32
Is there an environmental monitor card in this box?, 0 - No, 1-AGS card present, wrong firmware, 2-AGS CARD present, firmware ok, 3-7000 support
Context
- MIB
- OLD-CISCO-ENV-MIB
- OID
.1.3.6.1.4.1.9.2.1.77- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- lenv
- Siblings
- 35
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| envTestPt5last mandatory Value of TestPt5 when last shutdown
occurred. | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.100 |
| envTestPt6last mandatory Value of TestPt6 when last shutdown
occurred. | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.101 |
| envTestPt1warn mandatory Is this test point at a warning level? | scalar | Enumeration | .1.3.6.1.4.1.9.2.1.102 |
| envTestPt2warn mandatory Is this test point at a warning level? | scalar | Enumeration | .1.3.6.1.4.1.9.2.1.103 |
| envTestPt3warn mandatory Is this test point at a warning level? | scalar | Enumeration | .1.3.6.1.4.1.9.2.1.104 |
| envTestPt4warn mandatory Is this test point at a warning level? | scalar | Enumeration | .1.3.6.1.4.1.9.2.1.105 |
| envTestPt5warn mandatory Is this test point at a warning level? | scalar | Enumeration | .1.3.6.1.4.1.9.2.1.106 |
| envTestPt6warn mandatory Is this test point at a warning level? | scalar | Enumeration | .1.3.6.1.4.1.9.2.1.107 |
| envFirmVersion mandatory Description of Environmental Card firmware | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.108 |
| envTechnicianID mandatory Technician ID | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.109 |
| envType mandatory The type of environmental card | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.110 |
| envBurnDate mandatory The calibration / burn in date | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.111 |
| envSerialNumber mandatory Serial Number of environmental monitor card | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.112 |
| envTestPt1Descr mandatory Description of the test point 1. Typically
ambient air or the temperature of air
entering the router | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.78 |
| envTestPt1Measure mandatory Current value of test point 1. Typically a
temperature in centigrade. | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.79 |
| envTestPt2Descr mandatory Description of the test point 2. Typically
airflow or the temperature of air leaving the
router | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.80 |
| envTestPt2Measure mandatory Current value of test point 2. Typically a
temperature in centigrade. | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.81 |
| envTestPt3Descr mandatory Description of the test point 3. Typically
+5 volt | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.82 |
| envTestPt3Measure mandatory Current value of test point 3. Typically the
value in millivolts of the +5v supply | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.83 |
| envTestPt4Descr mandatory Description of the test point 4. Typically
+12 volt | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.84 |
| envTestPt4Measure mandatory Current value of test point 4. Typically the
value in millivolts of the +12v supply | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.85 |
| envTestPt5Descr mandatory Description of the test point 5. Typically
-12 volt | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.86 |
| envTestPt5Measure mandatory Current value of test point 5. Typically the
value in millivolts of the -12v supply | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.87 |
| envTestPt6Descr mandatory Description of the test point 6. Typically
-5 volt | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.9.2.1.88 |
| envTestPt6Measure mandatory Current value of test point 6. Typically the
value in millivolts of the -5v supply | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.89 |
| envTestPt1MarginVal mandatory Value at which the router will shutdown.
Typically the ambient air temperature that
will shut the router down. (e.g. 43) | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.90 |
| envTestPt2MarginVal mandatory Value at which the router will shutdown.
Typically the airflow air temperature that
will shut the router down. (e.g. 58) | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.91 |
| envTestPt3MarginPercent mandatory +/- Percentage that will shut the router
down, (e.g. 10%) typically +5 volt | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.92 |
| envTestPt4MarginPercent mandatory +/- Percentage that will shut the router
down, (e.g. 15%) typically +12 volt | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.93 |
| envTestPt5MarginPercent mandatory +/- Percentage that will shut the router
down, (e.g. 15%) typically -12 volt | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.94 |
| envTestPt6MarginPercent mandatory +/- Percentage that will shut the router
down, (e.g. 10%) typically -5 volt | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.95 |
| envTestPt1last mandatory Value of TestPt1 when last shutdown
occurred. | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.96 |
| envTestPt2last mandatory Value of TestPt2 when last shutdown
occurred. | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.97 |
| envTestPt3last mandatory Value of TestPt3 when last shutdown
occurred. | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.98 |
| envTestPt4last mandatory Value of TestPt4 when last shutdown
occurred. | scalar | Integer32 | .1.3.6.1.4.1.9.2.1.99 |