ogUpsOutputTruePower
OG-STATUSv2-MIB ·
.1.3.6.1.4.1.25049.17.14.1.34
Object
The current value of real power (Watts). Negative if unavailable.
Context
- MIB
- OG-STATUSv2-MIB
- OID
.1.3.6.1.4.1.25049.17.14.1.34- Type
- column
- Access
- readonly
- Status
- current
- Units
- Watts
- Parent
- ogUpsEntry
- Table
- ogUpsTable
- Siblings
- 34
Syntax
Watts SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ogUpsIndex Index within the UPS status table. | column | Integer32 | .1.3.6.1.4.1.25049.17.14.1.1 |
| ogUpsBatteryState The current state of the UPS battery. | column | Enumeration | .1.3.6.1.4.1.25049.17.14.1.10 |
| ogUpsBatteryRunTime Battery runtime (seconds). Negative if unavailable | column | seconds Integer32 | .1.3.6.1.4.1.25049.17.14.1.11 |
| ogUpsBatteryRunTimeLow Estimated remaining battery runtime when UPS switches to Low
Battery. Negative if unavailable. | column | seconds Integer32 | .1.3.6.1.4.1.25049.17.14.1.12 |
| ogUpsBatteryRunTimeRestart Minimum battery runtime for UPS restart after power-off
(seconds). Negative if unavailable. | column | seconds Integer32 | .1.3.6.1.4.1.25049.17.14.1.13 |
| ogUpsBatteryCharge Estimated percent of Battery charge remaining. Negative if
unavailable. | column | percent Integer32 | .1.3.6.1.4.1.25049.17.14.1.14 |
| ogUpsBatteryVoltage The magnitude of the current battery voltage. Negative if
unavailable. | column | 0.1 Volt DC SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.15 |
| ogUpsBatteryNominalVoltage Nominal battery voltage (V). Negative if unavailable. | column | 0.1 Volt DC SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.16 |
| ogUpsBatteryCurrent The UPS battery current. Negative if unavailable. | column | 0.1 Amp DC SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.17 |
| ogUpsBatteryNominalCurrent The nominal UPS battery current. Negative if unavailable. | column | 0.1 Amp DC SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.18 |
| ogUpsBatteryTemperature The UPS battery temperature. Negative if unavailable. | column | degrees SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.19 |
| ogUpsName The ID of this UPS. | column | OctetString | .1.3.6.1.4.1.25049.17.14.1.2 |
| ogUpsInputFrequency Input line frequency (Hz). Negative if unavailable. | column | Hz SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.20 |
| ogUpsInputNominalFrequency Nominal input line frequency (Hz). Negative if unavailable. | column | Hz SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.21 |
| ogUpsInputVoltage The magnitude of the UPS input voltage. Negative if
unavailable. | column | RMS Volts SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.22 |
| ogUpsInputNominalVoltage The nominal input voltage. Negative if unavailable. | column | RMS Volts SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.23 |
| ogUpsInputCurrent The input current. Negative if unavailable. | column | 0.1 RMS Amp SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.24 |
| ogUpsInputNominalCurrent The nominal input current. Negative if unavailable. | column | 0.1 RMS Amp SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.25 |
| ogUpsOutputFrequency Output line frequency (Hz). Negative if unavailable. | column | Hz SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.26 |
| ogUpsOutputNominalFrequency Nominal output line frequency (Hz). Negative if unavailable. | column | Hz SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.27 |
| ogUpsOutputVoltage The magnitude of the UPS output voltage. Negative if
unavailable. | column | RMS Volts SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.28 |
| ogUpsOutputNominalVoltage The nominal magnitude of the UPS output voltage. Negative if
unavailable. | column | RMS Volts SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.29 |
| ogUpsDescription A description of this UPS. | column | OctetString | .1.3.6.1.4.1.25049.17.14.1.3 |
| ogUpsOutputCurrent The magnitude of the UPS input current. Negative if
unavailable. | column | 0.1 RMS Amp SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.30 |
| ogUpsOutputNominalCurrent The nominal magnitude of the UPS input current. Negative if
unavailable. | column | 0.1 RMS Amp SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.31 |
| ogUpsOutputLoad Estimated percent of UPS power capacity being used. | column | percent Integer32 | .1.3.6.1.4.1.25049.17.14.1.32 |
| ogUpsOutputPower The current value of apparent power (Volt-Amps).
Negative if unavailable. | column | Volt-Amps SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.33 |
| ogUpsCounter Number of alerts triggered on the UPS | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.25049.17.14.1.35 |
| ogUpsType The UPS driver type. | column | OctetString | .1.3.6.1.4.1.25049.17.14.1.4 |
| ogUpsLogEnabled The logging status of the UPS | column | Enumeration | .1.3.6.1.4.1.25049.17.14.1.5 |
| ogUpsConnectType How the UPS device is being monitored. | column | Enumeration | .1.3.6.1.4.1.25049.17.14.1.6 |
| ogUpsState The current state the UPS is running in. | column | Enumeration | .1.3.6.1.4.1.25049.17.14.1.7 |
| ogUpsTemperature The UPS temperature. Negative if unavailable. | column | degrees SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.8 |
| ogUpsHumidity The UPS humidity. Negative if unavailable. | column | percent SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25049.17.14.1.9 |