oaLdOAmplifierCardAlarmStatus

OADWDM-MIB · .1.3.6.1.4.1.6926.1.41.12.2.1.20

Object

column mandatory OctetString
The Optical Amplifier Alarms.
This object is organised as a bit map. Each bit represents an alarm.
If the object is zero - no alarm is active.
0x0000 ('0000 0000 0000 0000'B) - Normal (No alarm)
0x0001 ('0000 0000 0000 0001'B) - Optical Input alarm
0x0002 ('0000 0000 0000 0010'B) - Optical Output alarm
0x0004 ('0000 0000 0000 0100'B) - Optical Input 2 (Back Reflection alarm for module EM800-OAR12)
0x0008 ('0000 0000 0000 1000'B) - Module Temperature alarm
0x0010 ('0000 0000 0001 0000'B) - Pump Temperature
0x0020 ('0000 0000 0010 0000'B) - Pump Drive Current alarm
0x0040 ('0000 0000 0100 0000'B) - Power Supply Voltage alarm
0x0080 ('0000 0000 1000 0000'B) - Auto-shutdown
0x0100 ('0000 0001 0000 0000'B) - Reflected Power High alarm
Any combination of the bits represent the combination of the alarms

Context

MIB
OADWDM-MIB
OID
.1.3.6.1.4.1.6926.1.41.12.2.1.20
Type
column
Access
readonly
Status
mandatory
Parent
oaLdOAmplifierCardInfoEntry
Table
oaLdOAmplifierCardInfoTable
Siblings
41

Syntax

OctetString

Values & Constraints

Object Constraints
range: 2-2

Related Objects

Sibling Objects