oaEfrmSfpInfoEnableStatus
OA-EFRM-CPE-MIB ·
.1.3.6.1.4.1.6926.1.16.10.1.2.1.42
Object
column
Enumeration
The current enable state of the sfp transceiver unknown - Unknown enabled - the sfp transceiver has been enabled disabled - the sfp transceiver has been diabled
Context
- MIB
- OA-EFRM-CPE-MIB
- OID
.1.3.6.1.4.1.6926.1.16.10.1.2.1.42- Type
- column
- Access
- readonly
- Status
- current
- Parent
- oaEfrmSfpInfoEntry
- Table
- oaEfrmSfpInfoTable
- Siblings
- 18
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| oaEfrmSfpInfoVendorName The sfp vendor name which is the full name of the corporation, a
commonly accepted abbreviation of the name of the corporation, the SCSI
company code for the corporation, or the s… | column | OctetString | .1.3.6.1.4.1.6926.1.16.10.1.2.1.24 |
| oaEfrmSfpInfoVendorOUI The sfp vendor organizationally unique identifier field (vendor OUI)
that contains the IEEE company identifier for the vendor. A value of
all zero in the 3 octet field indicates t… | column | OctetString | .1.3.6.1.4.1.6926.1.16.10.1.2.1.25 |
| oaEfrmSfpInfoVendorPN The sfp vendor part number (Vendor PN) or product name if the
Vendor PN is unspecified, the null string will be returned | column | OctetString | .1.3.6.1.4.1.6926.1.16.10.1.2.1.26 |
| oaEfrmSfpInfoVendorRev The transceiver vendor's product revision number (Vendor Rev) if the
Vendor Rev is unspecified, the null string will be returned | column | OctetString | .1.3.6.1.4.1.6926.1.16.10.1.2.1.27 |
| oaEfrmSfpInfoLaserWavelength Nominal Transmitter output wavelength at room temperature.
Units: 0.01 Nano Meter(nm) | column | 0.01 Nano Meter(nm) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6926.1.16.10.1.2.1.28 |
| oaEfrmSfpInfoIdentifier The type of serial transceiver
unknown - Unknown or unspecified
other - Vendor specific
gbic - GBIC
fixed - Module/connector soldered to motherboard
sfp - SFP transceiver
xbi300pi… | column | Enumeration | .1.3.6.1.4.1.6926.1.16.10.1.2.1.3 |
| oaEfrmSfpInfoVendorSN The Sfp vendor serial number (Vendor SN) if the Vendor SN is
unspecified, the null string will be returned | column | OctetString | .1.3.6.1.4.1.6926.1.16.10.1.2.1.32 |
| oaEfrmSfpInfoVendorDate The Vendor's date. Formated: YY MM DD | column | OctetString | .1.3.6.1.4.1.6926.1.16.10.1.2.1.33 |
| oaEfrmSfpInfoVendorSpecLotCode The Vendor Specific Lot code. A null value indicates that
the lot code is unspecified. | column | OctetString | .1.3.6.1.4.1.6926.1.16.10.1.2.1.34 |
| oaEfrmSfpInfoVendorSpecData Vendor Specific Information which can be read from the SFP transceiver
(Reference: SFF-8472, revision 9.3 - Registers 96-127 ) | column | OctetString | .1.3.6.1.4.1.6926.1.16.10.1.2.1.35 |
| oaEfrmSfpInfoDiagnosticPowerType The diagnostic monitoring receive power type in the SFP transceiver.
unknown - Unknown
avarage - Received power measurement type is avarage
oma - Received power measurement type i… | column | Enumeration | .1.3.6.1.4.1.6926.1.16.10.1.2.1.36 |
| oaEfrmSfpInfoDigitalDiagnostic The diagnostic monitoring implemented in the SFP transceiver.
unknown - Unknown
digitalDiagMonitoring - Digital diagnostic monitoring
implemented.
noDigita… | column | Enumeration | .1.3.6.1.4.1.6926.1.16.10.1.2.1.37 |
| oaEfrmSfpInfoDiagCalibration The diagnostic calibration in the SFP transceiver.
unknown - Unknown
ExternalCalibration - External Calibration
InternalCalibration - Internal Calibration | column | Enumeration | .1.3.6.1.4.1.6926.1.16.10.1.2.1.38 |
| oaEfrmSfpInfoVendorSpecId The vendor specific identifier. This Object will be set to
value other than null only if oaEfrmSfpInfoIdentifier returns a value
of other | column | OctetString | .1.3.6.1.4.1.6926.1.16.10.1.2.1.4 |
| oaEfrmSfpInfoInstalledStatus The current installed state of the sfp transceiver
unknown - Unknown
notInstalled - the SFP transceiver is not installed
installed - the sfp transceiver is installed | column | Enumeration | .1.3.6.1.4.1.6926.1.16.10.1.2.1.40 |
| oaEfrmSfpInfofaultStatus The current fault state of the sfp transceiver
unknown - Unknown
fault - the sfp transceiver is faulty
operational - the sfp transceiver is working properly | column | Enumeration | .1.3.6.1.4.1.6926.1.16.10.1.2.1.41 |
| oaEfrmSfpInfoConnector The type of external connector provided
unknown - Unknown or unspecified
other - Vendor specific
sc - SC
fcs1cc - Fibre Channel Style 1 copper connector
fcs2cc - Fibre Channel Sty… | column | Enumeration | .1.3.6.1.4.1.6926.1.16.10.1.2.1.8 |
| oaEfrmSfpInfoVendorSpecConnector The type of vendor specific Connector. This Object will be set to
value other than null only if oaEfrmSfpInfoConnector returns a value of
other. | column | OctetString | .1.3.6.1.4.1.6926.1.16.10.1.2.1.9 |