nbsStackSlotReset
NSTACK-MIB ·
.1.3.6.1.4.1.629.1.50.4.5.1.11
Object
column
mandatory
r/w
Enumeration
This object is used to reset the corresponding Slot Module.
Context
- MIB
- NSTACK-MIB
- OID
.1.3.6.1.4.1.629.1.50.4.5.1.11- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- nbsStackSlotEntry
- Table
- nbsStackSlotTable
- Siblings
- 13
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | running |
2 | reset |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| nbsStackSlotIndex mandatory This object identifies the Slot#
for which this entry contains information. | column | Integer32 | .1.3.6.1.4.1.629.1.50.4.5.1.1 |
| nbsStackSlotUplinkModulesNumber mandatory This object identifies the number of the Uplink Modules
in the Slot. | column | Integer32 | .1.3.6.1.4.1.629.1.50.4.5.1.10 |
| nbsStackSlotIp mandatory Ip address of the slot (if it has it; if it hasn't - 0.0.0.0). | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.629.1.50.4.5.1.12 |
| nbsStackSlotHwVers mandatory This object holds the Software Version of the Slot Module. | column | Integer32 | .1.3.6.1.4.1.629.1.50.4.5.1.13 |
| nbsStackSlotSwVers mandatory This object holds the Hardware Version of the Slot Module. | column | Integer32 | .1.3.6.1.4.1.629.1.50.4.5.1.14 |
| nbsStackSlotType mandatory Slot Types:
1=empty - Slot is Empty;
2=unknown - Slot is of the Unknown type;
3=standAlone - Stand Alone Device;
4=universal - Slot including Uplink Modules of the different types… | column | Enumeration | .1.3.6.1.4.1.629.1.50.4.5.1.2 |
| nbsStackSlotMgmtStatus mandatory Slot Module Management Status:
master - Master Slot Module;
slave - Slave Slot Module. | column | Enumeration | .1.3.6.1.4.1.629.1.50.4.5.1.3 |
| nbsStackSlotPortsMaxNumber mandatory This object identifies the Maximum possible Ports Number in the Slot. | column | Integer32 | .1.3.6.1.4.1.629.1.50.4.5.1.4 |
| nbsStackSlotPortsNumber mandatory This object identifies the Real Ports Number in the Slot. | column | Integer32 | .1.3.6.1.4.1.629.1.50.4.5.1.5 |
| nbsStackSlotFirstPort mandatory This object identifies the number of the First Port
in the Slot, according to the Stack Ports Numeration. | column | Integer32 | .1.3.6.1.4.1.629.1.50.4.5.1.6 |
| nbsStackSlotOperStatus mandatory Slot Oper Status:
switchedOff - Slot is Switched-off;
enabled - Slot is enabled;
disabled - Slot is disabled;
changing - Slot is changing. | column | Enumeration | .1.3.6.1.4.1.629.1.50.4.5.1.7 |
| nbsStackSlotAdminStatus mandatory Slot Admin Status:
enabled - Slot is enabled;