ocnSecondaryState
NORTEL-OME40G-FAC-MIB ·
.1.3.6.1.4.1.562.68.11.3.1.1.1.1.18
Object
column
RFC1213-MIBDisplayString
Secondary state for the facility. A facility can have more than one secondary state as different combinations of the individual secondary state. It is represented as a string to capture all the combinations. Those combinations along with the Primary state are used to compute the admin state. Can be any combination of flt, sgeo, lpbk, discd, ts, wrkrx, wrktx.
Context
- MIB
- NORTEL-OME40G-FAC-MIB
- OID
.1.3.6.1.4.1.562.68.11.3.1.1.1.1.18- Type
- column
- Access
- readonly
- Status
- current
- Parent
- nnOCnEntry
- Table
- nnOCnTable
- Siblings
- 19
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ocnRowStatus This attribute is used to manage rows in the
facility entry | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.1 |
| oChTxMaxOcnPwr Maximum Optical Channel transmit power | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.10 |
| oChRxActOcnPwr Actual Optical Channel receive power.
This variable is available upon GET-EXACT operations. No
value is returned with GET-NEXT. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.11 |
| oChRxMinOcnPwr Minimum Optical Channel receive power. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.12 |
| oChRxMaxOcnPwr Maximum Optical Channel receive power. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.13 |
| expSectionTraceMsg Expected section trace message.
This variable contains data during GET
operations only. GET-NEXT returns No Assigned Value | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.14 |
| incSectionTraceMsg Incoming section trace message
This variable contains data during GET
operations only. GET-NEXT returns No Assigned Value | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.15 |
| ocnLoopbackType Nothing is returned if Loopback is not active;
otherwise the facility is returned. | column | LoopbackType | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.16 |
| ocnPrimaryState Primary State of the faciltiy. Can only be modified
by changing the admin state. | column | PrimaryState | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.17 |
| ocnAdminState This is a write-only variable. The user can restore
or remove facilities using this command. You restore
a facility by setting this variable to IS and remove
it by setting it to O… | column | AdminState | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.19 |
| stFormat Section trace format | column | Enumeration | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.2 |
| ocnAID Facility AID as received from TL1. This should include
the FAC type, shelf id, slot, and port. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.20 |
| expSTrc Expected section trace | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.3 |
| stfMode Section trace alarming mode | column | Enumeration | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.4 |
| eBerTh Excessive Bit rate threshold | column | Integer32 | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.5 |
| ocnPortMode Port mode can eithter be SONET or SDH | column | Enumeration | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.6 |
| ocnLaserOffFarEndFail It can either be Enabled or Disabled. | column | Status | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.7 |
| oChTxActOcnPwr Actual Optical Channel transmit power.
This variable is available upon GET-EXACT operations. No
value is returned with GET-NEXT. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.8 |
| oChTxMinOcnPwr Minimum Optical Channel transmit power | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.562.68.11.3.1.1.1.1.9 |