currentAlarmUpLimitThreshold
NMS-EPON-OLT-PON ·
.1.3.6.1.4.1.3320.101.6.2.1.21
Object
column
mandatory
r/w
Integer32
The upper threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 1310.
Context
- MIB
- NMS-EPON-OLT-PON
- OID
.1.3.6.1.4.1.3320.101.6.2.1.21- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- ponOpticsParameterAlarmSetEntry
- Table
- ponOpticsParameterAlarmSetTable
- Siblings
- 24
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-1310
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ifIndex mandatory The only diid of PON port in System. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.1 |
| temperatureAlarmUpLimitClearThreshold mandatory The upper threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is 1280. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.10 |
| temperatureAlarmLowLimitEnable mandatory Enable or disable the alarm of PON low temperature. 1-enable, 2-disable. Default is disable. | column | Enumeration | .1.3.6.1.4.1.3320.101.6.2.1.11 |
| temperatureAlarmLowLimitThreshold mandatory The low threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is -1280. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.12 |
| temperatureAlarmLowLimitClearThreshold mandatory The low threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is -1280. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.13 |
| voltageAlarmUpLimitEnable mandatory Enable or disable the alarm of PON high voltage. 1-enable, 2-disable. Default is disable. | column | Enumeration | .1.3.6.1.4.1.3320.101.6.2.1.14 |
| voltageAlarmUpLimitThreshold mandatory The upper threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 65. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.15 |
| voltageAlarmUpLimitClearThreshold mandatory The upper threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 65. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.16 |
| voltageAlarmLowLimitEnable mandatory Enable or disable the alarm of PON low voltage. 1-enable, 2-disable. Default is disable. | column | Enumeration | .1.3.6.1.4.1.3320.101.6.2.1.17 |
| voltageAlarmLowLimitThreshold mandatory The low threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 0. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.18 |
| voltageAlarmLowLimitClearThreshold mandatory The low threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 0. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.19 |
| txPowerAlarmUpLimitEnable mandatory Enable or disable the alarm of PON hign TX power. 1-enable, 2-disable. Default is disable. | column | Enumeration | .1.3.6.1.4.1.3320.101.6.2.1.2 |
| currentAlarmUpLimitEnable mandatory Enable or disable the alarm of PON high current. 1-enable, 2-disable. Default is disable. | column | Enumeration | .1.3.6.1.4.1.3320.101.6.2.1.20 |
| currentAlarmUpLimitClearThreshold mandatory The upper threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 1310. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.22 |
| currentAlarmLowLimitEnable mandatory Enable or disable the alarm of PON hign TX power. 1-enable, 2-disable. Default is disable. | column | Enumeration | .1.3.6.1.4.1.3320.101.6.2.1.23 |
| currentAlarmLowLimitThreshold mandatory The low threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 0. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.24 |
| currentAlarmLowLimitClearThreshold mandatory The low threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 0. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.25 |
| txPowerAlarmUpLimitThreshold mandatory The upper threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.3 |
| txPowerAlarmUpLimitClearThreshold mandatory The upper threshold of tx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is 82. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.4 |
| txPowerAlarmLowLimitEnable mandatory Enable or disable the alarm of PON low TX power. 1-enable, 2-disable. Default is disable. | column | Enumeration | .1.3.6.1.4.1.3320.101.6.2.1.5 |
| txPowerAlarmLowLimitThreshold mandatory The low threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is -400. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.6 |
| txPowerAlarmLowLimitClearThreshold mandatory The low threshold tx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is -400. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.7 |
| temperatureAlarmUpLimitEnable mandatory Enable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable. | column | Enumeration | .1.3.6.1.4.1.3320.101.6.2.1.8 |
| temperatureAlarmUpLimitThreshold mandatory The upper threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is 1280. | column | Integer32 | .1.3.6.1.4.1.3320.101.6.2.1.9 |