upsCfgQSK2Status
NEXT-UPS-MIB ·
.0.1.1.11.31
Object
scalar
Enumeration
Get QSK 2 status
Context
- MIB
- NEXT-UPS-MIB
- OID
.0.1.1.11.31- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- upsConfig
- Siblings
- 44
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | disable |
1 | enable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsCfgAlarmbypass Setting this object enable /disable alarm bypass mode | scalar | Enumeration | .0.1.1.11.1 |
| upsCfgBatteryOSC Setting this object to enable/disable battery open status check | scalar | Enumeration | .0.1.1.11.10 |
| upsCfgAllowShort3times Setting this object to enable/disable short 3 times | scalar | Enumeration | .0.1.1.11.11 |
| upsCfgColdstart Setting this object to cold start ups | scalar | Enumeration | .0.1.1.11.12 |
| upsCfgBypassNotAllowed Setting this object to enable/disable bypass mode | scalar | Enumeration | .0.1.1.11.13 |
| upsCfgBatterylowprotect Setting this object to enable/disable battery low protect | scalar | Enumeration | .0.1.1.11.14 |
| upsCfgP1progoutletcontrol Setting this object to enable/disable p1 programmable outlet control (battery mode) | scalar | Enumeration | .0.1.1.11.15 |
| upsCfgP2progoutletcontrol Setting this object to enable/disable p2 programmable outlet control (battery mode) | scalar | Enumeration | .0.1.1.11.16 |
| upsCfgInverterShortClear Setting this object to enable/disable Inverter short clear function | scalar | Enumeration | .0.1.1.11.17 |
| upsCfgSitefaildetection Setting this object to enable/disable site fail detection | scalar | Enumeration | .0.1.1.11.18 |
| upsCfgBatNumInParallel Battery numbers in parallel (battery numbers setting) | scalar | Integer32 | .0.1.1.11.19 |
| upsCfgAlarmbattery Setting this object enable/disable alarm battery mode | scalar | Enumeration | .0.1.1.11.2 |
| upsCfgBatNumInSeries Battery numbers in series (battery numbers setting) | scalar | Integer32 | .0.1.1.11.20 |
| upsCfgBypassmaxvoltage Bypass mode max voltage | scalar | 0.1 Volts Integer32 | .0.1.1.11.21 |
| upsCfgBypassminvoltage Bypass mode min voltage | scalar | 0.1 Volts Integer32 | .0.1.1.11.22 |
| upsCfgBypassmaxfrequency Bypass mode max frequency ,for 50 HZ (510..600) for 60HZ (610..700) | scalar | 0.1 Hertz Integer32 | .0.1.1.11.23 |
| upsCfgBypassminfrequency Bypass mode min frequency, for 50HZ (400..490) for 60Hz (500..590) | scalar | 0.1 Hertz Integer32 | .0.1.1.11.24 |
| upsCfgECOmaxvoltage ECO mode max voltage | scalar | 0.1 Volts Integer32 | .0.1.1.11.25 |
| upsCfgECOminvoltage ECO mode min voltage | scalar | 0.1 Volts Integer32 | .0.1.1.11.26 |
| upsCfgFreeRunMaxFrequency Free run mode max frequency | scalar | 0.1 Hertz Integer32 | .0.1.1.11.27 |
| upsCfgFreeRunMinFrequency Free run mode min frequency | scalar | 0.1 Hertz Integer32 | .0.1.1.11.28 |
| upsCfgEPOStatus Get EPO status,configured by mamual | scalar | Enumeration | .0.1.1.11.29 |
| upsCfgAutoReboot Setting this object enable/disable auto reboot | scalar | Enumeration | .0.1.1.11.3 |
| upsCfgQSK1Status Get QSK 1 status | scalar | Enumeration | .0.1.1.11.30 |
| upsCfgQSKT1Delaytime Get QSKT 1 time delay | scalar | minutes Integer32 | .0.1.1.11.32 |
| upsCfgQSKT2Delaytime Get QSKT 2 time delay | scalar | minutes Integer32 | .0.1.1.11.33 |
| upsCfgConstantPhaseAngle setting this object to Enable/disable Constant Phase Angle function | scalar | Enumeration | .0.1.1.11.34 |
| upsCfgLimiRunOnBatMode Enable/disable limited runtime on battery mode | scalar | Enumeration | .0.1.1.11.37 |
| upsCfgChargingCurrent Set charging current to battery . | scalar | 0.1 Amp DC Integer32 | .0.1.1.11.38 |
| upsCfgBatSeftCheckVolt BatTest until battery voltage lower than <nnn> | scalar | 0.1 Volts Integer32 | .0.1.1.11.39 |
| upsCfgBypasswhenupsoff Setting this object start/stop bypass when ups off | scalar | Enumeration | .0.1.1.11.4 |
| upsCfgOverChargVolt set over charging voltage to per battery | scalar | 0.1 Volts Integer32 | .0.1.1.11.40 |
| upsCfgBattUnderVolt set battery under voltage of setting value.value is a number ranging from 200V to 240V | scalar | 0.1 Volts Integer32 | .0.1.1.11.41 |
| upsCfgBattLowVolt set battery low voltage of setting value.it is 10 to 40V high than battery under voltage.
it is 10 to 40V high than battery under voltage.default 20.
it means that the battery … | scalar | 0.1 Volts Integer32 | .0.1.1.11.42 |
| upsCfgIn1VoltHLoss set input1 voltage high loss point. | scalar | 0.1 Volts Integer32 | .0.1.1.11.43 |
| upsCfgIn1VoltLLoss set input1 voltage low loss point. | scalar | 0.1 Volts Integer32 | .0.1.1.11.44 |
| upsCfgIn2VoltHLoss set input2 voltage high loss point. | scalar | 0.1 Volts Integer32 | .0.1.1.11.45 |
| upsCfgIn2VoltLLoss set input2 voltage low loss point. | scalar | 0.1 Volts Integer32 | .0.1.1.11.46 |
| upsCfgBatteryTurnOn Enable/disable battery turn on. | scalar | Enumeration | .0.1.1.11.47 |
| upsCfgBatterDDP Setting this object to enable/disable battery deep-discharge protection | scalar | Enumeration | .0.1.1.11.5 |
| upsCfgConvertermode Setting this object to enable/disable converter mode | scalar | Enumeration | .0.1.1.11.6 |
| upsCfgECOmode Setting this object to enable/disable ECO mode | scalar | Enumeration | .0.1.1.11.7 |
| upsCfgAdvanceECOmode Setting this object to enable/disable advance ECO mode | scalar | Enumeration | .0.1.1.11.8 |
| upsCfgGreenPowerFunction Setting this object to enable/disable green power function | scalar | Enumeration | .0.1.1.11.9 |