solarDefMinRChargVolt
NEXT-UPS-MIB ·
.0.1.2.9.47
Object
scalar
0.1W Integer32
The max charging voltage
Context
- MIB
- NEXT-UPS-MIB
- OID
.0.1.2.9.47- Type
- scalar
- Access
- readonly
- Status
- current
- Units
- 0.1W
- Parent
- solarDefValue
- Siblings
- 46
Syntax
0.1W Integer32
Values & Constraints
Object Constraints
range: 0-999
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| solarDefGridOutVolHLoss The default setting value of grid output voltage high loss point | scalar | 0.1 Volt DC Integer32 | .0.1.2.9.1 |
| solarDefLowLimitPVVol The default setting value The lowest limit of PV input voltage | scalar | 0.1 vol Integer32 | .0.1.2.9.10 |
| solarDefPVHVolMPPT The default setting value The PV input high voltage for MPPT | scalar | 0.1 Wt Integer32 | .0.1.2.9.11 |
| solarDefPVLVolMPPT The default setting value The PV input low voltage for MPPT | scalar | 0.1 vol Integer32 | .0.1.2.9.12 |
| solarDefMaxOutPower The default setting value Max output power | scalar | 0.1 vol Integer32 | .0.1.2.9.13 |
| solarDefAverageVolHLoss The default setting value Long time grid average voltage high loss point | scalar | 0.1 Wt Integer32 | .0.1.2.9.14 |
| solarDefLCDSleepTime The default setting value LCD sleep time | scalar | 30s Integer32 | .0.1.2.9.15 |
| solarDefBatteryNum The default setting value Battery piece number | scalar | UPS-MIBNonNegativeInteger | .0.1.2.9.16 |
| solarDefBattTtlCapacit The default setting value Battery total capacity | scalar | 0.1 Ah UPS-MIBNonNegativeInteger | .0.1.2.9.17 |
| solarDefChargerCurrent The default setting value Charger current | scalar | 0.1 A UPS-MIBNonNegativeInteger | .0.1.2.9.18 |
| solarDefMaxChargeVol The default setting the max charging voltage | scalar | 0.1 V Integer32 | .0.1.2.9.19 |
| solarDefGridOutVolLLoss The default setting value of grid output voltage lowloss point | scalar | 0.1 Volt DC Integer32 | .0.1.2.9.2 |
| solarDefMaxChargeCurr The default setting the max charging current | scalar | 0.1 A Integer32 | .0.1.2.9.20 |
| solarDefWaiteTimeFeed The default setting waiting time for feeding | scalar | second Integer32 | .0.1.2.9.21 |
| solarDefMaxGridOutVolHLoss The max grid output voltage high loss point | scalar | 0.1 Volt DC Integer32 | .0.1.2.9.22 |
| solarDefMinGridOutVolHLoss The min grid output voltage high loss point | scalar | 0.1 Volt DC Integer32 | .0.1.2.9.23 |
| solarDefMaxGridOutVolLLoss The max grid output voltage low loss point | scalar | 0.1 Volt DC Integer32 | .0.1.2.9.24 |
| solarDefMinGridOutVolLLoss The min grid output voltage low loss point | scalar | 0.1 Volt DC Integer32 | .0.1.2.9.25 |
| solarDefMaxGridOutFreqHLoss The max grid output frequency high loss point | scalar | 0.1 HZ Integer32 | .0.1.2.9.26 |
| solarDefMinGridOutFreqHLoss The min grid output frequency high loss point | scalar | 0.1 HZ Integer32 | .0.1.2.9.27 |
| solarDefMaxGridOutFreqLLoss The max grid output frequency low loss point | scalar | 0.1 HZ Integer32 | .0.1.2.9.28 |
| solarDefMinGridOutFreqLLoss The min grid output frequency low loss point | scalar | 0.1 HZ Integer32 | .0.1.2.9.29 |
| solarDefGridOutFreqHLoss The default setting value Grid output frequency high loss point | scalar | 0.1 HZ Integer32 | .0.1.2.9.3 |
| solarDefMaxWaiteTimeFeed The max waiting time for feeding | scalar | second Integer32 | .0.1.2.9.30 |
| solarDefMinWaiteTimeFeed The min waiting time for feeding | scalar | second Integer32 | .0.1.2.9.31 |
| solarDefMaxMaxFChargVolt The max voltage for max floating charging voltage | scalar | 0.1Volt Integer32 | .0.1.2.9.32 |
| solarDefMinMaxFChargVolt The min voltage for max floating charging voltage | scalar | 0.1Volt Integer32 | .0.1.2.9.33 |
| solarDefMaxMaxRChargCurr The upper limit of max charging current(real charging) | scalar | 0.1A Integer32 | .0.1.2.9.34 |
| solarDefMinMaxRChargCurr The lower limit of max charging current(real charging) | scalar | 0.1A Integer32 | .0.1.2.9.35 |
| solarDefMaxMaxPVInputVolt The upper limit of max PV input voltage | scalar | 0.1Volt Integer32 | .0.1.2.9.36 |
| solarDefMinMaxPVInputVolt The lower limit of max PV input voltage | scalar | 0.1Volt Integer32 | .0.1.2.9.37 |
| solarDefMaxMinPVInputVolt The upper limit of min PV input voltage | scalar | 0.1Volt Integer32 | .0.1.2.9.38 |
| solarDefMinMinPVInputVolt The lowest limit of min PV input voltage | scalar | 0.1Volt Integer32 | .0.1.2.9.39 |
| solarDefGridOutFreqLLoss The default setting value Grid output frequency low loss point | scalar | 0.1 HZ Integer32 | .0.1.2.9.4 |
| solarDefMaxHighMPPTVolt The max MPPT high voltage | scalar | 0.1Volt Integer32 | .0.1.2.9.40 |
| solarDefMinHighMPPTVolt The min MPPT high voltage | scalar | 0.1Volt Integer32 | .0.1.2.9.41 |
| solarDefMaxLowMPPTVolt The max MPPT low voltage | scalar | 0.1Volt Integer32 | .0.1.2.9.42 |
| solarDefMinLowMPPTVolt The min MPPT low voltage | scalar | 0.1Volt Integer32 | .0.1.2.9.43 |
| solarDefMaxOutputPower The max output power | scalar | 0.1W Integer32 | .0.1.2.9.44 |
| solarDefMinOutputPower The min output power | scalar | 0.1W Integer32 | .0.1.2.9.45 |
| solarDefMaxRChargVolt The min charging voltage | scalar | 0.1W Integer32 | .0.1.2.9.46 |
| solarDefGridInVolHLoss The default setting value Grid input voltage high loss point | scalar | 0.1 VA Integer32 | .0.1.2.9.5 |
| solarDefGridInVolLLoss The default setting value Grid input voltage low loss point | scalar | 0.1 Wt Integer32 | .0.1.2.9.6 |
| solarDefGridInFreqHLoss The default setting value Grid input frequency high loss point | scalar | 0.1 vol Integer32 | .0.1.2.9.7 |
| solarDefGridInFreqLLoss The default setting value Grid input frequency low loss point | scalar | 0.1 Wt Integer32 | .0.1.2.9.8 |
| solarDefUpLimitPVVol The default setting value The upper limit of PV input voltage | scalar | 0.1 vol Integer32 | .0.1.2.9.9 |