solarBatSecondsOnBattery
NEXT-UPS-MIB ·
.0.1.2.3.2
Object
scalar
seconds Integer32
If the unit is on battery power, the elapsed time since the solar last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. -1 shall be returned if the unit is not on battery power.
Context
- MIB
- NEXT-UPS-MIB
- OID
.0.1.2.3.2- Type
- scalar
- Access
- readonly
- Status
- current
- Units
- seconds
- Parent
- solarBattery
- Siblings
- 15
Syntax
seconds Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| solarBatStatus The indication of the status in the solar system's batteries. | scalar | Enumeration | .0.1.2.3.1 |
| solarBatNBatchargCurrent The present negative battery charging current. | scalar | 0.1 Amp DC Integer32 | .0.1.2.3.10 |
| solarBatPBatDischargCurrent The present positive battery discharging current. | scalar | 0.1 Amp DC Integer32 | .0.1.2.3.11 |
| solarBatNBatDischargCurrent The present negative battery discharging current. | scalar | 0.1 Amp DC Integer32 | .0.1.2.3.12 |
| solarBatTemperature The ambient temperature at or near the solar Battery
casing. | scalar | degrees 0.1 Centigrade Integer32 | .0.1.2.3.13 |
| solarBatNumberInSeries The number of battery in series. | scalar | UPS-MIBPositiveInteger | .0.1.2.3.14 |
| solarBatNumberInParallel The number of battery in Parallel. | scalar | UPS-MIBPositiveInteger | .0.1.2.3.15 |
| solarBatChargingCurrent Charging Current. | scalar | Integer32 | .0.1.2.3.16 |
| solarBatEstMinutesRemaining An estimate of the time to battery charge depletion
under the present load conditions if the utility power
is off and remains off, or if it were to be lost and
remain off. | scalar | minutes Integer32 | .0.1.2.3.3 |
| solarBatEstChargeRemaining An estimate of the battery charge remaining expressed
as a percent of full charge. | scalar | percent Integer32 | .0.1.2.3.4 |
| solarBatPBatVoltage The magnitude of the present Positive battery voltage. | scalar | 0.1 Volt DC UPS-MIBNonNegativeInteger | .0.1.2.3.5 |
| solarBatNBatVoltage The magnitude of the present negative battery voltage. | scalar | 0.1 Volt DC UPS-MIBNonNegativeInteger | .0.1.2.3.6 |
| solarBatPBatCurrent The positive battery present current. | scalar | 0.1 Amp DC Integer32 | .0.1.2.3.7 |
| solarBatNBatCurrent The present negative battery current. | scalar | 0.1 Amp DC Integer32 | .0.1.2.3.8 |
| solarBatPBatChargCurrent The Positive battery charging current. | scalar | 0.1 Amp DC Integer32 | .0.1.2.3.9 |