ntcAupcCtrlRefTerm
NEWTEC-AUPCCONTROLLER-MIB ·
.1.3.6.1.4.1.5835.5.2.4200.1.6
Object
scalar
r/w
Unsigned32
The reference terminal that feeds the AUPC algorithm. Terminal '0' indicates that the input of every terminal can be used.
Context
- MIB
- NEWTEC-AUPCCONTROLLER-MIB
- OID
.1.3.6.1.4.1.5835.5.2.4200.1.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- ntcAupcCtrlObjects
- Siblings
- 6
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-65277
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ntcAupcCtrlEnable Enable or disable the AUPC controller | scalar | NEWTEC-TC-MIBNtcEnable | .1.3.6.1.4.1.5835.5.2.4200.1.1 |
| ntcAupcCtrlNominalModPower Nominal modulator output power setting in dBm. Adjustable in steps of 0.1 dBm.
Float represented as integer is scaled by a factor of 10. i.e. a value of
'-103' means '-10.3' dBm N… | scalar | dBm Integer32 | .1.3.6.1.4.1.5835.5.2.4200.1.2 |
| ntcAupcCtrlMaximumModPower Maximum modulator output power setting in dBm. Adjustable in steps of 0.1 dBm.
Float represented as integer is scaled by a factor of 10. i.e. a value of
'-103' means '-10.3' dBm N… | scalar | dBm Integer32 | .1.3.6.1.4.1.5835.5.2.4200.1.3 |
| ntcAupcCtrlMaximumPowerStepUp Maximum step size by which the modulator power level is raised per second
Float represented as integer is scaled by a factor of 10. i.e. a value of '10'
means '1' dBm/s | scalar | dBm/s Integer32 | .1.3.6.1.4.1.5835.5.2.4200.1.4 |
| ntcAupcCtrlMaximumPowerStepDown Maximum step size by which the modulator power level is decreased per second
Float represented as integer is scaled by a factor of 10. i.e. a value of '10'
means '1' dBm/s | scalar | dBm/s Integer32 | .1.3.6.1.4.1.5835.5.2.4200.1.5 |
| ntcAupcCtrlMonitoring Container holding ntcAupcCtrlMonitoring definitions. | node | - | .1.3.6.1.4.1.5835.5.2.4200.1.7 |