nbsSigCondVodPortDispersionOper
NBS-SIGCOND-MIB ·
.1.3.6.1.4.1.629.227.60.2.1.5
Object
column
Integer32
Actual dispersion in ps/nm
Not supported value: 0x80000000
Context
- MIB
- NBS-SIGCOND-MIB
- OID
.1.3.6.1.4.1.629.227.60.2.1.5- Type
- column
- Access
- readonly
- Status
- current
- Parent
- nbsSigCondVodPortEntry
- Table
- nbsSigCondVodPortTable
- Siblings
- 11
Syntax
Integer32
Values & Constraints
Object Constraints
range: -100000-100000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| nbsSigCondVodPortIfIndex The Mib2 ifIndex of the dispersion compensation port. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.629.227.60.2.1.1 |
| nbsSigCondVodPortDispersionGridOffsetCenter The center frequency of the offset, in GigaHertz
(GHz), unless FreqExponent != 9.
Not supported value: 0 | column | Integer32 | .1.3.6.1.4.1.629.227.60.2.1.10 |
| nbsSigCondVodPortDispersionGridOffsetMin In GigaHertz (GHz), unless FreqExponent != 9.
Not supported value: 0x80000000 | column | Integer32 | .1.3.6.1.4.1.629.227.60.2.1.11 |
| nbsSigCondVodPortDispersionGridOffsetMax In GigaHertz (GHz), unless FreqExponent != 9.
Not supported value: 0x80000000 | column | Integer32 | .1.3.6.1.4.1.629.227.60.2.1.12 |
| nbsSigCondVodPortDispersionGridOffsetStep The spacing of the allowable grid offsets that this port
supports, in GigaHertz (GHz), unless FreqExponent != 9.
Not supported value: 0 | column | Integer32 | .1.3.6.1.4.1.629.227.60.2.1.13 |
| nbsSigCondVodPortDispersionGridOffsetExponent The exponent of all the GridOffset values (including
GridOffsetStep).
9 (the default) indicates all units are in GigaHertz (GHz). | column | Integer32 | .1.3.6.1.4.1.629.227.60.2.1.14 |
| nbsSigCondVodPortDispersionGridOffsetAdmin In GigaHertz (GHz), unless FreqExponent != 9.
Not supported value: 0x80000000 | column | Integer32 | .1.3.6.1.4.1.629.227.60.2.1.15 |
| nbsSigCondVodPortDispersionGridOffsetOper In GigaHertz (GHz), unless FreqExponent != 9.
Not supported value: 0x80000000 | column | Integer32 | .1.3.6.1.4.1.629.227.60.2.1.16 |
| nbsSigCondVodPortDispersionMin Minimum allowed dispersion compensation in ps/nm.
Not supported value: 0x80000000 | column | Integer32 | .1.3.6.1.4.1.629.227.60.2.1.2 |
| nbsSigCondVodPortDispersionMax Maximum allowed dispersion compensation in ps/nm.
Not supported value: 0x80000000 | column | Integer32 | .1.3.6.1.4.1.629.227.60.2.1.3 |
| nbsSigCondVodPortDispersionAdmin Desired dispersion compensation in ps/nm.
Not supported value: 0x80000000 | column | Integer32 | .1.3.6.1.4.1.629.227.60.2.1.4 |