nbsOdsysTrapCcRemoved
NBS-ODSYS-MIB ·
.1.3.6.1.4.1.629.228.100.0.133
Object
notification
Triggered when control card is removed from chassis
Context
- MIB
- NBS-ODSYS-MIB
- OID
.1.3.6.1.4.1.629.228.100.0.133- Type
- notification
- Status
- current
- Parent
- nbsOdsysEvents
- Siblings
- 17
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| nbsOdsysTrapCcFailed Triggered when nbsOdsysCcOperationalStatus transitions to
bad (2) | notification | - | .1.3.6.1.4.1.629.228.100.0.131 |
| nbsOdsysTrapCcRestored Triggered when nbsOdsysCcOperationalStatus transitions to
good (3) | notification | - | .1.3.6.1.4.1.629.228.100.0.132 |
| nbsOdsysTrapCcInserted Triggered when control card is inserted into chassis | notification | - | .1.3.6.1.4.1.629.228.100.0.134 |
| nbsOdsysTrapCcThermLevelBad Sent when nbsOdsysCcThermLevel changes to anything but
statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.30 |
| nbsOdsysTrapCcThermLevelOk Sent when nbsOdsysCcThermLevel changes to statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.31 |
| nbsOdsysTrapFtThermLevelBad Sent when fan tray's nbsOdsysFtThermLevel changes to
anything but statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.40 |
| nbsOdsysTrapFtThermLevelOk Sent when fan tray's nbsOdsysFtThermLevel changes to
statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.41 |
| nbsOdsysTrapPsThermLevelBad Sent when power supply's nbsOdsysPsThermLevel changes to
anything but statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.50 |
| nbsOdsysTrapPsThermLevelOk Sent when power supply's nbsOdsysPsThermLevel changes to
statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.51 |
| nbsOdsysTrapPsVInLevelBad Sent when power supply's nbsOdsysPsVInLevel changes to
anything but statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.60 |
| nbsOdsysTrapPsVInLevelOk Sent when power supply's nbsOdsysPsVInLevel changes to
statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.61 |
| nbsOdsysTrapPsVOutLevelBad Sent when power supply's nbsOdsysPsVOutLevel changes to
anything but statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.70 |
| nbsOdsysTrapPsVOutLevelOk Sent when power supply's nbsOdsysPsVOutLevel changes to
statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.71 |
| nbsOdsysTrapPsIInLevelBad Sent when power supply's nbsOdsysPsIInLevel changes to
anything but statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.80 |
| nbsOdsysTrapPsIInLevelOk Sent when power supply's nbsOdsysPsIInLevel changes to
statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.81 |
| nbsOdsysTrapPsIOutLevelBad Sent when power supply's nbsOdsysPsIOutLevel changes to
anything but statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.90 |
| nbsOdsysTrapPsIOutLevelOk Sent when power supply's nbsOdsysPsIOutLevel changes to
statusGood (4) | notification | - | .1.3.6.1.4.1.629.228.100.0.91 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| nbsOdsysCcChasIndex The nbsCmmcChassisIndex of this control card's chassis | column | Integer32 | .1.3.6.1.4.1.629.228.3.1.1.1 |
| nbsOdsysCcBayIndex The control card slot/bay # | column | Integer32 | .1.3.6.1.4.1.629.228.3.1.1.2 |