configValueEntry
NATEKS-MIB ·
.1.3.6.1.4.1.4249.2.4.100.2.1
Object
row
Configuration item.
Context
- MIB
- NATEKS-MIB
- OID
.1.3.6.1.4.1.4249.2.4.100.2.1- Type
- row
- Status
- current
- Parent
- configValueTable
- Table
- configValueTable
- Children
- 10
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| valueId A unique index of configuration value. It is constant
at least until main software of the module changes. | column | Integer32 | .1.3.6.1.4.1.4249.2.4.100.2.1.1 |
| valueBackup Backup value of configuration variable. | column | OctetString | .1.3.6.1.4.1.4249.2.4.100.2.1.10 |
| valueGroup Index of values' configuration group in the configGroupTable. | column | IntegerIndex | .1.3.6.1.4.1.4249.2.4.100.2.1.2 |
| valueName A unique name of configuration value. It is constant
at least until main software of the module changes. Usually,
it remains constant through the lifecycle of the product. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4249.2.4.100.2.1.3 |
| valueGroupName Name of values' configuration group. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4249.2.4.100.2.1.4 |
| valueType Value type. | column | Enumeration | .1.3.6.1.4.1.4249.2.4.100.2.1.5 |
| valueStatus Change status for a value.
All values of valueType setNow(1) have unchanged(1) status.
Status for values of valueType applyConfirm(2):
Initially, … | column | Enumeration | .1.3.6.1.4.1.4249.2.4.100.2.1.6 |
| valueStartup Startup value of configuration variable. Write operation changes
valueStartup for values of valueType afterReset(3),
valueRunning for values of valueType setNow(1),
valueNew for v… | column | OctetString | .1.3.6.1.4.1.4249.2.4.100.2.1.7 |
| valueRunning Running value of configuration variable. Write operation changes
valueStartup for values of valueType afterReset(3),
valueRunning for values of valueType setNow(1),
valueNew for v… | column | OctetString | .1.3.6.1.4.1.4249.2.4.100.2.1.8 |
| valueNew New value of configuration variable. Write operation changes
valueStartup for values of valueType afterReset(3),
valueRunning for values of valueType setNow(1),
valueNew for value… | column | OctetString | .1.3.6.1.4.1.4249.2.4.100.2.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| valueId A unique index of configuration value. It is constant
at least until main software of the module changes. | column | Integer32 | .1.3.6.1.4.1.4249.2.4.100.2.1.1 |