genEquipSynchronizationPRCRegeneratorDirection
MWRM-NETWORK-MIB ·
.1.3.6.1.4.1.2281.10.8.3.7
Object
scalar
r/w
Enumeration
This parameter sets the direction in which the frequency signal is transported, in the case of electrical GBE interfaces. Notice that for optical interfaces, this parameter has no effect.
Context
- MIB
- MWRM-NETWORK-MIB
- OID
.1.3.6.1.4.1.2281.10.8.3.7- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- genEquipSynchronization
- Siblings
- 14
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | line-to-radio |
1 | radio-to-line |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| genEquipSynchronizationSrcTable Synchronization source table. | table | - | .1.3.6.1.4.1.2281.10.8.3.1 |
| genEquipSynchronizationNodeMode This parameter allows forcing a certain source as the active source for the system reference clock.
When forced, the active source is specified by genEquipSynchronizationForceSour… | scalar | Enumeration | .1.3.6.1.4.1.2281.10.8.3.10 |
| genEquipSynchronizationForceSource This parameter determines which source number will be forced as active when genEquipSynchronizationNodeMode is set to force. | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.11 |
| genEquipSynchronizationSystemReferenceQuality This parameter shows the current quality of the system reference clock | scalar | Enumeration | .1.3.6.1.4.1.2281.10.8.3.12 |
| genEquipSynchronizationRegeneratorSSMAdmin This parameter determines whether or not in pipe mode the system generates SSM messages | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.13 |
| genEquipSynchronizationPWClkExport This parameter determines whether the system reference clock is exported toward the PWE3 T-Card;
This reference can be exported towards front panel using ExportClkFrontPannel or u… | scalar | Enumeration | .1.3.6.1.4.1.2281.10.8.3.14 |
| genEquipSynchronizationPipeTable The table shows pipe interfaces. | table | - | .1.3.6.1.4.1.2281.10.8.3.20 |
| genEquipSynchronizationPTP | node | - | .1.3.6.1.4.1.2281.10.8.3.21 |
| genEquipSynchronizationRadioClkSrcSource This parameters determines whether the system reference frequency is transported through the radio.
0 indicates that the outgoing signal takes its clock from an independant local … | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.3 |
| genEquipSynchronizationSDHClkSrcSource This parameters determines whether the system reference frequency is transported
through the interface. if value is 0 it indicates that the outgoing signal takes its
clock from … | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.4 |
| genEquipSynchronizationPDHClkSrcTable Synchronization source table. | table | - | .1.3.6.1.4.1.2281.10.8.3.5 |
| genEquipSynchronizationPRCRegeneratorMode This parameter sets the IDU to point-to-point PRC quality frequency distribution mode.
Notice that this is relevant only for smart pipe applications | scalar | MWRM-UNIT-MIBEnableDisable | .1.3.6.1.4.1.2281.10.8.3.6 |
| genEquipSynchronizationSrcRevertiveTimer this parameter sets the timeout (in seconds) for a counter which is set once
an interface recovers from a failure; after this timeout the interface will be considered
stable and c… | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.8 |
| genEquipSynchronizationSrcActiveSyncSourceIndex The active synchronization source. | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.9 |