genEquipSynchronizationPDHClkSrcTable
MWRM-NETWORK-MIB ·
.1.3.6.1.4.1.2281.10.8.3.5
Object
table
Synchronization source table.
Context
- MIB
- MWRM-NETWORK-MIB
- OID
.1.3.6.1.4.1.2281.10.8.3.5- Type
- table
- Status
- current
- Parent
- genEquipSynchronization
- Siblings
- 14
- Children
- 1
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| genEquipSynchronizationSrcTable Synchronization source table. | table | - | .1.3.6.1.4.1.2281.10.8.3.1 |
| genEquipSynchronizationNodeMode This parameter allows forcing a certain source as the active source for the system reference clock.
When forced, the active source is specified by genEquipSynchronizationForceSour… | scalar | Enumeration | .1.3.6.1.4.1.2281.10.8.3.10 |
| genEquipSynchronizationForceSource This parameter determines which source number will be forced as active when genEquipSynchronizationNodeMode is set to force. | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.11 |
| genEquipSynchronizationSystemReferenceQuality This parameter shows the current quality of the system reference clock | scalar | Enumeration | .1.3.6.1.4.1.2281.10.8.3.12 |
| genEquipSynchronizationRegeneratorSSMAdmin This parameter determines whether or not in pipe mode the system generates SSM messages | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.13 |
| genEquipSynchronizationPWClkExport This parameter determines whether the system reference clock is exported toward the PWE3 T-Card;
This reference can be exported towards front panel using ExportClkFrontPannel or u… | scalar | Enumeration | .1.3.6.1.4.1.2281.10.8.3.14 |
| genEquipSynchronizationPipeTable The table shows pipe interfaces. | table | - | .1.3.6.1.4.1.2281.10.8.3.20 |
| genEquipSynchronizationPTP | node | - | .1.3.6.1.4.1.2281.10.8.3.21 |
| genEquipSynchronizationRadioClkSrcSource This parameters determines whether the system reference frequency is transported through the radio.
0 indicates that the outgoing signal takes its clock from an independant local … | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.3 |
| genEquipSynchronizationSDHClkSrcSource This parameters determines whether the system reference frequency is transported
through the interface. if value is 0 it indicates that the outgoing signal takes its
clock from … | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.4 |
| genEquipSynchronizationPRCRegeneratorMode This parameter sets the IDU to point-to-point PRC quality frequency distribution mode.
Notice that this is relevant only for smart pipe applications | scalar | MWRM-UNIT-MIBEnableDisable | .1.3.6.1.4.1.2281.10.8.3.6 |
| genEquipSynchronizationPRCRegeneratorDirection This parameter sets the direction in which the frequency signal is transported,
in the case of electrical GBE interfaces.
Notice that for optical interfaces, this parameter has no… | scalar | Enumeration | .1.3.6.1.4.1.2281.10.8.3.7 |
| genEquipSynchronizationSrcRevertiveTimer this parameter sets the timeout (in seconds) for a counter which is set once
an interface recovers from a failure; after this timeout the interface will be considered
stable and c… | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.8 |
| genEquipSynchronizationSrcActiveSyncSourceIndex The active synchronization source. | scalar | Integer32 | .1.3.6.1.4.1.2281.10.8.3.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| genEquipSynchronizationPDHClkSrcEntry Synchronization source table. | row | - | .1.3.6.1.4.1.2281.10.8.3.5.1 |