defaultDOValueAllChannelFunctionCode
MOXA-IAW5x50A_IO-MIB ·
.1.3.6.1.4.1.8691.2.21.1.5.2.14
Object
scalar
Enumeration
Default function code of DO Value all channel in modbus.
Context
- MIB
- MOXA-IAW5x50A_IO-MIB
- OID
.1.3.6.1.4.1.8691.2.21.1.5.2.14- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- defaultModbusAddress
- Siblings
- 47
Syntax
Enumeration
Values & Constraints
Enumerated Values
2 | fc03_HoldingRegister |
3 | fc04_InputRegister |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| defaultDOValueStartAddress Default start address of DO Value. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.1 |
| defaultDOPulseStatusReferenceAddress Default reference address of DO Pulse Start/Stop. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.10 |
| defaultDOPulseStatusTotalchannels Default total channels of DO Pulse Start/Stop in modbus. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.11 |
| defaultDOPulseStatusDatatype Default data type of DO Pulse Start/Stop in modbus. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.12 |
| defaultDOValueAllChannelStartAddress Default start address of DO Value all channel in modbus. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.13 |
| defaultDOValueAllChannelReadWrite Default permission of DO Value all channel in modbus. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.15 |
| defaultDOValueAllChannelReferenceAddress Default reference address of DO Value all channel in modbus. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.16 |
| defaultDOValueAllChannelTotalchannels Default total channels of DO Value all channel in modbus. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.17 |
| defaultDOValueAllChannelDatatype Default data type of DO Value all channel. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.18 |
| defaultDIValueStartAddress Default start address of DI Value. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.19 |
| defaultDOValueFunctionCode Default function code of DO Value. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.2 |
| defaultDIValueFunctionCode Default function code of DI Value. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.20 |
| defaultDIValueReadWrite Default permission of DI Value in modbus. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.21 |
| defaultDIValueReferenceAddress Default reference address of DI Value. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.22 |
| defaultDIValueTotalchannels Default total channels of DI Value in modbus. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.23 |
| defaultDIValueDatatype Default data type of DI Value. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.24 |
| defaultDICounterValueStartAddress Default start address of DI Counter Value. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.25 |
| defaultDICounterValueFunctionCode Default function code of DI Counter Value. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.26 |
| defaultDICounterValueReadWrite Default permission of DI Counter Value in modbus. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.27 |
| defaultDICounterValueReferenceAddress Default reference address of DI Counter Value. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.28 |
| defaultDICounterValueTotalchannels Default total channels of DI Counter Value in modbus. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.29 |
| defaultDOValueReadWrite Default permission of DO Value in modbus. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.3 |
| defaultDICounterValueDatatype Default data type of DI Counter Value. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.30 |
| defaultDIValueAllChannelStartAddress Default start address of DI Value All Channel. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.31 |
| defaultDIValueAllChannelFunctionCode Default function code of DI Value All Channel. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.32 |
| defaultDIValueAllChannelReadWrite Default permission of DI Value All Channel in modbus. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.33 |
| defaultDIValueAllChannelReferenceAddress Default reference address of DI Value All Channel. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.34 |
| defaultDIValueAllChannelTotalchannels Default total channels of DI Value All Channel in modbus. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.35 |
| defaultDIValueAllChannelDatatype Default data type of DI Value All Channel. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.36 |
| defaultDICounterStartStartAddress Default start address of DI Counter Start/Stop. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.37 |
| defaultDICounterStartFunctionCode Default function code of DI Counter Start/Stop. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.38 |
| defaultDICounterStartReadWrite Default permission of DI Counter Start/Stop in modbus. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.39 |
| defaultDOValueReferenceAddress Default reference address of DO Value. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.4 |
| defaultDICounterStartReferenceAddress Default reference address of DI Counter Start/Stop. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.40 |
| defaultDICounterStartTotalchannels Default total channels of DI Counter Start/Stop in modbus. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.41 |
| defaultDICounterStartDatatype Default data type of DI Counter Start/Stop. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.42 |
| defaultDICounterClearStartAddress Default start address of DI Counter Clear. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.43 |
| defaultDICounterClearFunctionCode Default function code of DI Counter Clear. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.44 |
| defaultDICounterClearReadWrite Default permission of DI Counter Clear in modbus. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.45 |
| defaultDICounterClearReferenceAddress Default reference address of DI Counter Clear. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.46 |
| defaultDICounterClearTotalchannels Default total channels of DI Counter Clear in modbus. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.47 |
| defaultDICounterClearDatatype Default data type of DI Counter Clear. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.48 |
| defaultDOValueTotalchannels Default total channels of DO Value in modbus. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.5 |
| defaultDOValueDatatype Default data type of DO Value. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.6 |
| defaultDOPulseStatusStartAddress Default start address of DO Pulse Start/Stop. | scalar | Integer32 | .1.3.6.1.4.1.8691.2.21.1.5.2.7 |
| defaultDOPulseStatusFunctionCode Default function code of DO Pulse Start/Stop. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.8 |
| defaultDOPulseStatusReadWrite Default permission of DO Pulse Start/Stop in modbus. | scalar | Enumeration | .1.3.6.1.4.1.8691.2.21.1.5.2.9 |