coolingDeviceProbeCapabilities
MIB-Dell-10892 ·
.1.3.6.1.4.1.674.10892.1.700.12.1.17
Object
column
mandatory
DellProbeCapabilities
0700.0012.0001.0017 This attribute defines the probe capabilities of the cooling device.
Context
- MIB
- MIB-Dell-10892
- OID
.1.3.6.1.4.1.674.10892.1.700.12.1.17- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- coolingDeviceTableEntry
- Table
- coolingDeviceTable
- Siblings
- 17
Syntax
DellProbeCapabilities
- Source
- DellProbeCapabilities
- Base type
Enumeration
Values & Constraints
Type Values
1 | upperNonCriticalThresholdSetCapable |
2 | lowerNonCriticalThresholdSetCapable |
4 | upperNonCriticalThresholdDefaultCapable |
8 | lowerNonCriticalThresholdDefaultCapable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| coolingDevicechassisIndex mandatory 0700.0012.0001.0001 This attribute defines the index (one based) of the
associated chassis. | column | DellObjectRange | .1.3.6.1.4.1.674.10892.1.700.12.1.1 |
| coolingDeviceUpperCriticalThreshold mandatory 0700.0012.0001.0010 This attribute defines the upper critical threshold
of the cooling device. The value is an integer representing fan speed
in revolutions per minute (RPM). It… | column | DellSigned32BitRange | .1.3.6.1.4.1.674.10892.1.700.12.1.10 |
| coolingDeviceUpperNonCriticalThreshold mandatory 0700.0012.0001.0011 This attribute defines the upper noncritical threshold
of the cooling device. The value is an integer representing fan speed
in revolutions per minute (RPM). … | column | DellSigned32BitRange | .1.3.6.1.4.1.674.10892.1.700.12.1.11 |
| coolingDeviceLowerNonCriticalThreshold mandatory 0700.0012.0001.0012 This attribute defines the lower noncritical threshold
of the cooling device. The value is an integer representing fan speed
in revolutions per minute (RPM). … | column | DellSigned32BitRange | .1.3.6.1.4.1.674.10892.1.700.12.1.12 |
| coolingDeviceLowerCriticalThreshold mandatory 0700.0012.0001.0013 This attribute defines the lower critical threshold
of the cooling device. The value is an integer representing fan speed
in revolutions per minute (RPM). It… | column | DellSigned32BitRange | .1.3.6.1.4.1.674.10892.1.700.12.1.13 |
| coolingDeviceLowerNonRecoverableThreshold mandatory 0700.0012.0001.0014 This attribute defines the lower nonrecoverable threshold
of the cooling device. The value is an integer representing fan speed
in revolutions per minute (RPM… | column | DellSigned32BitRange | .1.3.6.1.4.1.674.10892.1.700.12.1.14 |
| coolingDevicecoolingUnitIndexReference mandatory 0700.0012.0001.0015 This attribute defines the index to the associated
cooling unit. | column | DellObjectRange | .1.3.6.1.4.1.674.10892.1.700.12.1.15 |
| coolingDeviceSubType mandatory 0700.0012.0001.0016 This attribute defines the subtype of the cooling device. | column | DellCoolingDeviceSubType | .1.3.6.1.4.1.674.10892.1.700.12.1.16 |
| coolingDeviceDiscreteReading mandatory 0700.0012.0001.0018 This attribute defines the reading for a cooling device
of type coolingDeviceSubTypeIsDiscrete. When the value for
coolingDeviceSubType is other than coolingD… | column | DellCoolingDeviceDiscreteReading | .1.3.6.1.4.1.674.10892.1.700.12.1.18 |
| coolingDeviceIndex mandatory 0700.0012.0001.0002 This attribute defines the index (one based) of the
cooling device. | column | DellObjectRange | .1.3.6.1.4.1.674.10892.1.700.12.1.2 |
| coolingDeviceStateCapabilities mandatory 0700.0012.0001.0003 This attribute defines the state capabilities of the
cooling device. | column | DellStateCapabilities | .1.3.6.1.4.1.674.10892.1.700.12.1.3 |
| coolingDeviceStateSettings mandatory 0700.0012.0001.0004 This attribute defines the state settings of the
cooling device. | column | DellStateSettings | .1.3.6.1.4.1.674.10892.1.700.12.1.4 |
| coolingDeviceStatus mandatory 0700.0012.0001.0005 This attribute defines the probe status of the
cooling device. | column | DellStatusProbe | .1.3.6.1.4.1.674.10892.1.700.12.1.5 |
| coolingDeviceReading mandatory 0700.0012.0001.0006 This attribute defines the reading for a cooling device
of subtype other than coolingDeviceSubTypeIsDiscrete. When the value
for coolingDeviceSubType is other… | column | DellSigned32BitRange | .1.3.6.1.4.1.674.10892.1.700.12.1.6 |
| coolingDeviceType mandatory 0700.0012.0001.0007 This attribute defines the type of the cooling device. | column | DellCoolingDeviceType | .1.3.6.1.4.1.674.10892.1.700.12.1.7 |
| coolingDeviceLocationName mandatory 0700.0012.0001.0008 This attribute defines the location name of the
cooling device. | column | DellString | .1.3.6.1.4.1.674.10892.1.700.12.1.8 |
| coolingDeviceUpperNonRecoverableThreshold mandatory 0700.0012.0001.0009 This attribute defines the upper nonrecoverable threshold
of the cooling device. The value is an integer representing fan speed
in revolutions per minute (RPM… | column | DellSigned32BitRange | .1.3.6.1.4.1.674.10892.1.700.12.1.9 |