mbgLtNgCmdSetTime

MBG-SNMP-LTNG-MIB · .1.3.6.1.4.1.5597.30.2.2

Object

scalar r/w SNMPv2-TCDisplayString
Reference time can be set via a date-time string in format:
yyyy-mm-dd hh:mm:ss
Time is interpreted as configured via web interface at menu:
'Receiver'->'Time Zone'
It is mandatory to unplug the receiver's antenna to make this work.
and strongly advised to execute a SNMPSET WITHOUT retries
and a timeout value greater than 60 seconds. Otherwise
there might come up unforeseen issues.
SNMPGET always returns default value.

Context

MIB
MBG-SNMP-LTNG-MIB
OID
.1.3.6.1.4.1.5597.30.2.2
Type
scalar
Access
readwrite
Status
current
Parent
mbgLtNgCommands
Siblings
1

Syntax

SNMPv2-TCDisplayString
Source
SNMPv2-TCDisplayString
Base type
OctetString

Values & Constraints

Type Constraints
range: 0..255

Related Objects

Sibling Objects