mbgLtNgCmdSetTime
MBG-SNMP-LTNG-MIB ·
.1.3.6.1.4.1.5597.30.2.2
Object
Reference time can be set via a date-time string in format: yyyy-mm-dd hh:mm:ss Time is interpreted as configured via web interface at menu: 'Receiver'->'Time Zone' It is mandatory to unplug the receiver's antenna to make this work. and strongly advised to execute a SNMPSET WITHOUT retries and a timeout value greater than 60 seconds. Otherwise there might come up unforeseen issues. SNMPGET always returns default value.
Context
- MIB
- MBG-SNMP-LTNG-MIB
- OID
.1.3.6.1.4.1.5597.30.2.2- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- mbgLtNgCommands
- Siblings
- 1
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| mbgLtNgCmdExecute Send a command to the timeserver to be executed;
Attention: Command should be executed with a timeout of 120 seconds and 0 retries | scalar | Enumeration | .1.3.6.1.4.1.5597.30.2.1 |