upsmConnCardType
LUXN-MIB ·
.1.3.6.1.4.1.4253.1.17.7.1.8
Object
column
mandatory
r/w
CardType
Module type connected to upsm port.
Context
- MIB
- LUXN-MIB
- OID
.1.3.6.1.4.1.4253.1.17.7.1.8- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- upsmPortEntry
- Table
- upsmPortTable
- Siblings
- 10
Syntax
CardType
- Source
- CardType
- Base type
Enumeration
Values & Constraints
Type Values
0 | empty |
1 | mpm |
2 | ocmu |
3 | ocmi |
4 | ofcm |
5 | ofcd |
6 | fadm |
7 | oppm |
8 | mcmt1 |
9 | oli |
10 | w4cd |
13 | w2cmd |
20 | osam |
21 | w4cm |
22 | rsm |
23 | upsm |
24 | ocme |
25 | oci |
26 | oxc |
27 | ocm10g |
29 | osamlp |
30 | osamhp |
33 | mcmesc |
34 | wfadm |
35 | mcme1 |
36 | md100-1 |
37 | md100-40 |
38 | tap |
39 | md100-5 |
40 | md100-10 |
41 | ocm10glr |
42 | bd-4 |
43 | bp-10 |
44 | unknown |
45 | dmm |
46 | bp-5 |
47 | mpm2 |
48 | osc |
49 | ocm2 |
50 | ocm10gf |
51 | ocm2-4g |
52 | oet |
53 | uob |
54 | fc8g |
55 | md100p |
56 | cwdm_bd4 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsmPortCardShelf mandatory The shelf the card is in. Valid values are: 1 to 2. | column | CardShelf | .1.3.6.1.4.1.4253.1.17.7.1.1 |
| upsmConnShelf mandatory The shelf the card conn to. Valid values are: 1 to 2. | column | ShelfInput | .1.3.6.1.4.1.4253.1.17.7.1.10 |
| upsmConnSlot mandatory The slot within the shelf the card conn to. To delete a
connection associated with a specified port, set this
variable to 0. | column | SlotInput | .1.3.6.1.4.1.4253.1.17.7.1.11 |
| upsmPortCardSlot mandatory The slot within the shelf the card is in. | column | SlotInput | .1.3.6.1.4.1.4253.1.17.7.1.2 |
| upsmPortType mandatory Type of the UPSM's port. The order is CLI compatible. | column | Enumeration | .1.3.6.1.4.1.4253.1.17.7.1.3 |
| upsmConnLocation mandatory The chassis's location of the card conn to. | column | CardLocation | .1.3.6.1.4.1.4253.1.17.7.1.4 |
| upsmConnIpAddress mandatory IpAddress of the connected node. User config. If local
connection, a set on it would return an error; would be automatically
be set to the IP address of the node | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.4253.1.17.7.1.5 |
| upsmConnChassisID mandatory Chassis ID of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the chassis Id of the local node | column | OctetString | .1.3.6.1.4.1.4253.1.17.7.1.6 |
| upsmConnSystemName mandatory System Name of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the sysetem name of the local node. | column | OctetString | .1.3.6.1.4.1.4253.1.17.7.1.7 |
| upsmConnPort mandatory Conn port for UPSM's port. Possible values based on
card types that can connect to UPSM are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B … | column | Integer32 | .1.3.6.1.4.1.4253.1.17.7.1.9 |