osamLaserBiasCurrent

LUXN-MIB · .1.3.6.1.4.1.4253.1.15.6.1.17

Object

column mandatory r/w Integer32
Constant current in mA to be used by the module when 
the operation mode is set to currentControlled. This 
value can't be set if operation mode is set to 
gainControlled.
Applicable only to OSAM module

Context

MIB
LUXN-MIB
OID
.1.3.6.1.4.1.4253.1.15.6.1.17
Type
column
Access
readwrite
Status
mandatory
Parent
osamEntry
Table
osamTable
Siblings
26

Syntax

Integer32

Values & Constraints

Object Constraints
range: 40-200

Related Objects

Sibling Objects