oetAdminState
LUXN-MIB ·
.1.3.6.1.4.1.4253.1.33.2.1.21
Object
column
mandatory
r/w
Enumeration
Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | disable |
2 | enable |
3 | na |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| oetCardLocation mandatory Location of the module. | column | CardLocation | .1.3.6.1.4.1.4253.1.33.2.1.1 |
| oetFwVersionID mandatory Firmware version. | column | VersionString | .1.3.6.1.4.1.4253.1.33.2.1.10 |
| oetFwDate mandatory Firmware release date and time. | column | DateAndTime | .1.3.6.1.4.1.4253.1.33.2.1.11 |
| oetModelType mandatory Model type of the module. | column | CardType | .1.3.6.1.4.1.4253.1.33.2.1.12 |
| oetName mandatory User configurable name of the module. | column | CardName | .1.3.6.1.4.1.4253.1.33.2.1.13 |
| oetCleiNum mandatory CLEI number of the module. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4253.1.33.2.1.14 |
| oetFpgaRevMB mandatory FPGA revision for the module's mother board. | column | Integer32 | .1.3.6.1.4.1.4253.1.33.2.1.15 |
| oetFpgaRevDB mandatory FPGA revision for the module's daughter board. | column | Integer32 | .1.3.6.1.4.1.4253.1.33.2.1.16 |
| oetCpldRev mandatory CPLD revision for the module. | column | Integer32 | .1.3.6.1.4.1.4253.1.33.2.1.17 |
| oetOpMode mandatory Operating Mode (1=Mux Mode, 2=Switch Mode). | column | Enumeration | .1.3.6.1.4.1.4253.1.33.2.1.18 |
| oetProtMode mandatory Mux Protection. | column | Enumeration | .1.3.6.1.4.1.4253.1.33.2.1.19 |
| oetCardShelf mandatory The shelf where the module resides. | column | CardShelf | .1.3.6.1.4.1.4253.1.33.2.1.2 |
| oetEAPSMode mandatory Ethernet Automatic Protection Switching. | column | Enumeration | .1.3.6.1.4.1.4253.1.33.2.1.20 |
| oetSetState mandatory Instruct the module to do a warmboot. A get on this will
always return 'other'. | column | Enumeration | .1.3.6.1.4.1.4253.1.33.2.1.22 |
| oetConfigInProgress mandatory Configured changes are pending, Apply Changes required
to finish. | column | Enumeration | .1.3.6.1.4.1.4253.1.33.2.1.23 |
| oetApplyChanges mandatory Update device with pending configuration changes.
Read returns 'na'. | column | Enumeration | .1.3.6.1.4.1.4253.1.33.2.1.24 |
| oetCardSlot mandatory The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To d… | column | SlotInput | .1.3.6.1.4.1.4253.1.33.2.1.3 |
| oetSerialNum mandatory Module serial number. | column | SerialString | .1.3.6.1.4.1.4253.1.33.2.1.4 |
| oetModelNum mandatory Module model number. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4253.1.33.2.1.5 |
| oetHwName mandatory Module hardware name. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4253.1.33.2.1.6 |
| oetHwVersionID mandatory Module hardware version. | column | VersionString | .1.3.6.1.4.1.4253.1.33.2.1.7 |
| oetMfgDate mandatory Date and Time of manufacturing of the module | column | DateAndTime | .1.3.6.1.4.1.4253.1.33.2.1.8 |
| oetFwName mandatory Module firmware name. | column | CardName | .1.3.6.1.4.1.4253.1.33.2.1.9 |