ocm4gName
LUXN-MIB ·
.1.3.6.1.4.1.4253.1.32.2.1.13
Object
column
mandatory
r/w
CardName
User configurable name of the module.
Context
- MIB
- LUXN-MIB
- OID
.1.3.6.1.4.1.4253.1.32.2.1.13- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- ocm4gEntry
- Table
- ocm4gTable
- Siblings
- 25
Syntax
CardName
- Source
- CardName
- Base type
OctetString
Values & Constraints
Type Constraints
range: 0..32
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ocm4gCardLocation mandatory Location of the module. | column | Enumeration | .1.3.6.1.4.1.4253.1.32.2.1.1 |
| ocm4gFwVersionID mandatory Firmware version. | column | VersionString | .1.3.6.1.4.1.4253.1.32.2.1.10 |
| ocm4gFwDate mandatory Firmware release date and time. | column | DateAndTime | .1.3.6.1.4.1.4253.1.32.2.1.11 |
| ocm4gModelType mandatory Model type of the module. | column | CardType | .1.3.6.1.4.1.4253.1.32.2.1.12 |
| ocm4gLink1LineRate mandatory Link 1 line rate. | column | Enumeration | .1.3.6.1.4.1.4253.1.32.2.1.14 |
| ocm4gLink1AutoDisable mandatory Flag to enable/disable automatic CPE disable for Link 1. | column | Enumeration | .1.3.6.1.4.1.4253.1.32.2.1.15 |
| ocm4gLink1LinkName mandatory Link 1 link name for fiber between the local and the
remote card. | column | LinkName | .1.3.6.1.4.1.4253.1.32.2.1.16 |
| ocm4gLink1PathID mandatory Link 1 path ID name associated with the module. Set input
equal to NULL will remove the card off the path
and also remove the path if no other modules are
associated with that … | column | PathIdName | .1.3.6.1.4.1.4253.1.32.2.1.17 |
| ocm4gLink2LineRate mandatory Link 2 line rate. | column | Enumeration | .1.3.6.1.4.1.4253.1.32.2.1.18 |
| ocm4gLink2AutoDisable mandatory Flag to enable/disable automatic CPE disable for Link 2. | column | Enumeration | .1.3.6.1.4.1.4253.1.32.2.1.19 |
| ocm4gCardShelf mandatory The shelf where the module resides. | column | CardShelf | .1.3.6.1.4.1.4253.1.32.2.1.2 |
| ocm4gLink2LinkName mandatory Link 2 link name for fiber between the local and the
remote card. | column | LinkName | .1.3.6.1.4.1.4253.1.32.2.1.20 |
| ocm4gLink2PathID mandatory Link 2 path ID name associated with the module. Set input
equal to NULL will remove the card off the path
and also remove the path if no other modules are
associated with that … | column | PathIdName | .1.3.6.1.4.1.4253.1.32.2.1.21 |
| ocm4gAdminState mandatory Administrative control for the module. Default
value is enable. When disabled, no alarms/events are
generated for the module. | column | Enumeration | .1.3.6.1.4.1.4253.1.32.2.1.22 |
| ocm4gSetState mandatory Instruct the module to do a warmboot. A get on this will
always return 'other'. | column | Enumeration | .1.3.6.1.4.1.4253.1.32.2.1.23 |
| ocm4gCleiNum mandatory CLEI number of the module. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4253.1.32.2.1.24 |
| ocm4gNumPorts mandatory Total port numbers on each OCM4G card. | column | Integer32 | .1.3.6.1.4.1.4253.1.32.2.1.25 |
| ocm4gFpgaRev mandatory FPGA revision for the module. | column | Integer32 | .1.3.6.1.4.1.4253.1.32.2.1.26 |
| ocm4gCardSlot mandatory The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To d… | column | SlotInput | .1.3.6.1.4.1.4253.1.32.2.1.3 |
| ocm4gSerialNum mandatory Module serial number. | column | SerialString | .1.3.6.1.4.1.4253.1.32.2.1.4 |
| ocm4gModelNum mandatory Module model number. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4253.1.32.2.1.5 |
| ocm4gHwName mandatory Module hardware name. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4253.1.32.2.1.6 |
| ocm4gHwVersionID mandatory Module hardware version. | column | VersionString | .1.3.6.1.4.1.4253.1.32.2.1.7 |
| ocm4gMfgDate mandatory Date and Time of manufacturing of the module | column | DateAndTime | .1.3.6.1.4.1.4253.1.32.2.1.8 |
| ocm4gFwName mandatory Module firmware name. | column | CardName | .1.3.6.1.4.1.4253.1.32.2.1.9 |