fadmPortCardSlot
LUXN-MIB ·
.1.3.6.1.4.1.4253.1.7.7.1.2
Object
column
mandatory
SlotInput
The slot within the shelf the card is in.
Context
- MIB
- LUXN-MIB
- OID
.1.3.6.1.4.1.4253.1.7.7.1.2- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- fadmPortEntry
- Table
- fadmPortTable
- Siblings
- 10
Syntax
SlotInput
- Source
- SlotInput
- Base type
Integer32
Values & Constraints
Type Constraints
range: 0..17
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fadmPortCardShelf mandatory The shelf the card is in. Valid values are: 1 to 2. | column | CardShelf | .1.3.6.1.4.1.4253.1.7.7.1.1 |
| fadmConnShelf mandatory The shelf the card conn to. Valid values are: 1 to 2. | column | ShelfInput | .1.3.6.1.4.1.4253.1.7.7.1.10 |
| fadmConnSlot mandatory The slot within the shelf the card conn to. To delete a
connection associated with a specified port, set this
variable to 0. | column | SlotInput | .1.3.6.1.4.1.4253.1.7.7.1.11 |
| fadmPortType mandatory Type of the FADM port. The order is CLI compatible.
For FADM model type, the ports are listed on the left column | column | Enumeration | .1.3.6.1.4.1.4253.1.7.7.1.3 |
| fadmConnLocation mandatory The chassis's location of the card conn to. | column | CardLocation | .1.3.6.1.4.1.4253.1.7.7.1.4 |
| fadmConnIpAddress mandatory IpAddress of the connected node. User config. If local
connection, a set on it would return an error; would be automatically
be set to the IP address of the node | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.4253.1.7.7.1.5 |
| fadmConnChassisID mandatory Chassis ID of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the chassis Id of the local node | column | OctetString | .1.3.6.1.4.1.4253.1.7.7.1.6 |
| fadmConnSystemName mandatory System Name of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the sysetem name of the local node. | column | OctetString | .1.3.6.1.4.1.4253.1.7.7.1.7 |
| fadmConnCardType mandatory Module type connected to fadm port. | column | CardType | .1.3.6.1.4.1.4253.1.7.7.1.8 |
| fadmConnPort mandatory Conn port for FADM's port. Possible values based on
card types that can be connected to are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B … | column | Integer32 | .1.3.6.1.4.1.4253.1.7.7.1.9 |