wdmCtrlGroupChannelStartupCommand
LUM-WDM-MIB ·
.1.3.6.1.4.1.8708.2.4.2.9.1.1.23
Object
column
LUM-TCCommandString
Initiates a safe startup sequence for all the
channels of selected group. If the administrative
status of the channel is 'down' or the channel is
not detected by the monitor unit, the system attempts
to detect the channel as follows:
1) The attenuation is set to its maximum value.
2) The attenuation is decreased until the channel is
detected by the monitor.
When the channel is detected, regulation of the
channel is started, ignoring the regulation range.
If the channel cannot be detected, channelStatus is
set to notFound. If regulation fails, channelStatus
is set to 'error' and an alarm is raised.
When the startup sequence is finished, the
administrative status of the channel is set to 'up'.
If a regulation is ongoing when the startup
procedure is initiated, the channel is put on a
waiting queue until the ongoing regulation is
finished. The startup queue has a limited length. If
the queue is filled up with waiting channels,
further startup commands will be blocked until all
the queued channels have been started.
Context
- MIB
- LUM-WDM-MIB
- OID
.1.3.6.1.4.1.8708.2.4.2.9.1.1.23- Type
- column
- Access
- readonly
- Status
- current
- Parent
- wdmCtrlGroupEntry
- Table
- wdmCtrlGroupTable
- Siblings
- 22
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wdmCtrlGroupIndex An index assigned to each entry. Index contains
information about group number, subrack, slot and
port. | column | Unsigned32 | .1.3.6.1.4.1.8708.2.4.2.9.1.1.1 |
| wdmCtrlGroupControlMode The current control group mode.
normal - regulation is performed at the interval
defined in General -> Regulation interval
commissioning - the regul… | column | Enumeration | .1.3.6.1.4.1.8708.2.4.2.9.1.1.10 |
| wdmCtrlGroupConfigurationCommand Select which control mode to use:
normal - regulation is performed at the interval
defined in General -> Regulation interval
commissioning - the reg… | column | LUM-TCCommandString | .1.3.6.1.4.1.8708.2.4.2.9.1.1.11 |
| wdmCtrlGroupForceRegulationCommand Starts a regulation manually | column | LUM-TCCommandString | .1.3.6.1.4.1.8708.2.4.2.9.1.1.12 |
| wdmCtrlGroupLockedRange To avoid frequent changes of attenuation, a range
can be defined around the wanted output power. A
control loop will not try to adjust power values
within the range. | column | Integer32 | .1.3.6.1.4.1.8708.2.4.2.9.1.1.13 |
| wdmCtrlGroupRegulationRange An offset below the wanted output power
at which the 'Current Power Out Of Range'
alarm shall be raised.
When the current output power is so
far below the wanted ou… | column | Unsigned32 | .1.3.6.1.4.1.8708.2.4.2.9.1.1.14 |
| wdmCtrlGroupRegulationLastChangeTime The time when the group was last regulated. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.8708.2.4.2.9.1.1.15 |
| wdmCtrlGroupCommissioningMode Alarm raised when the group is put in commissioning
mode.
A: Commissioning mode is used
D: Normal mode | column | LUM-TCFaultStatus | .1.3.6.1.4.1.8708.2.4.2.9.1.1.16 |
| wdmCtrlGroupAssociateChannel Creates one or several control channel objects and
associates them to the selected group.
User needs to specify:
- The board where the added channels… | column | LUM-TCCommandString | .1.3.6.1.4.1.8708.2.4.2.9.1.1.17 |
| wdmCtrlGroupNoOfChannels The current number of channels associated with this
group. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.8708.2.4.2.9.1.1.18 |
| wdmCtrlGroupStatus The regulation status for the group
starting - the system is starting up
noRegulation - the group contains no channels to
regulate
… | column | Enumeration | .1.3.6.1.4.1.8708.2.4.2.9.1.1.19 |
| wdmCtrlGroupName The management name of the group,
for example 'group:1' (group:[groupNumber]). | column | LUM-TCMgmtNameString | .1.3.6.1.4.1.8708.2.4.2.9.1.1.2 |
| wdmCtrlGroupTimeLeft The remaining time (in seconds) to next regulation. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.8708.2.4.2.9.1.1.20 |
| wdmCtrlGroupOutputPowerMismatch The total output power of the OCM differs by
more than 1.4dB from the monitor port
insertion loss value of the OA.
A: The total output power of the OCM differs from… | column | LUM-TCFaultStatus | .1.3.6.1.4.1.8708.2.4.2.9.1.1.21 |
| wdmCtrlGroupTotalPower Total power of channels associated to
this group, based on OCM measurements. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.8708.2.4.2.9.1.1.22 |
| wdmCtrlGroupDescr User configurable label. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.8708.2.4.2.9.1.1.3 |
| wdmCtrlGroupGroupNumber A unique number identifying the group. | column | Unsigned32 | .1.3.6.1.4.1.8708.2.4.2.9.1.1.4 |
| wdmCtrlGroupSubrack The number of the subrack where the monitor unit is
located. | column | LUM-TCSubrackNumber | .1.3.6.1.4.1.8708.2.4.2.9.1.1.5 |
| wdmCtrlGroupSlot The number of the slot where the monitor is located. | column | LUM-TCSlotNumber | .1.3.6.1.4.1.8708.2.4.2.9.1.1.6 |
| wdmCtrlGroupPort The monitor port where the group is connected.
Each character represents a port number, as shown:
a->1, b->2, c->3, d->4, e->5, f->6, g->7, h->8. | column | Enumeration | .1.3.6.1.4.1.8708.2.4.2.9.1.1.7 |
| wdmCtrlGroupMonitorName The management name of the monitor port,
for example 'ocm:1:2:1-A'
([monitortype]:[subrack]:[slot]:[port]). | column | LUM-TCMgmtNameString | .1.3.6.1.4.1.8708.2.4.2.9.1.1.8 |
| wdmCtrlGroupAdminStatus The administrative state for the group.
down - The group is de-activated. No regulations
will be performed.
service - The group is activated but alar… | column | LUM-TCBoardOrInterfaceAdminStatus | .1.3.6.1.4.1.8708.2.4.2.9.1.1.9 |