ifOpticalFecUId
LUM-IFOPTICAL-MIB ·
.1.3.6.1.4.1.8708.2.48.2.5.1.1.11
Object
column
r/w
Unsigned32
Unique Identifier for the entry
Context
- MIB
- LUM-IFOPTICAL-MIB
- OID
.1.3.6.1.4.1.8708.2.48.2.5.1.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ifOpticalFecEntry
- Table
- ifOpticalFecTable
- Siblings
- 11
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ifOpticalFecIndex An index assigned to each entry. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.8708.2.48.2.5.1.1.1 |
| ifOpticalFecTypeUnavailable Fec type unavailable.
The inserted transceiver does not support the
requested fec type.
alarm: A transceiver with other supported fec type
han… | column | LUM-TCFaultStatus | .1.3.6.1.4.1.8708.2.48.2.5.1.1.10 |
| ifOpticalFecDecModeMismatch FEC decoding mode mismatch. | column | LUM-TCFaultStatusWithNA | .1.3.6.1.4.1.8708.2.48.2.5.1.1.12 |
| ifOpticalFecName The management name of the FEC object,
for example 'lineFec:1:2:1-2', where the first number
indicates subrack, the second slot number and the
third/fourth are the physical port n… | column | LUM-TCMgmtNameString | .1.3.6.1.4.1.8708.2.48.2.5.1.1.2 |
| ifOpticalFecConnIfBasicIfIndex An index describing to which index in ifBasicIf table
this object is related to. | column | LUM-TCUnsigned32WithNA | .1.3.6.1.4.1.8708.2.48.2.5.1.1.3 |
| ifOpticalFecType Set type of FEC.
g709 - 1st generation FEC according to
ITU-T G.709 (near 6 dB coding gain).
g9751I4 - FEC according to G975.1 I.4. O… | column | LUM-TCFecType | .1.3.6.1.4.1.8708.2.48.2.5.1.1.4 |
| ifOpticalFecTxSignalStatus The state for outgoing (TX) signal
of the interface.
down - A major fault has occurred.
degraded - The signal quality is impaired.
up … | column | LUM-TCSignalStatusWithNA | .1.3.6.1.4.1.8708.2.48.2.5.1.1.5 |
| ifOpticalFecRxSignalStatus The state for incoming (RX) signal
of the interface.
down - A major fault has occurred.
degraded - The signal quality is impaired.
up … | column | LUM-TCSignalStatusWithNA | .1.3.6.1.4.1.8708.2.48.2.5.1.1.6 |
| ifOpticalFecFailure FEC failure.
Too many errors to get valid FEC statistics. It is not
possible to run control loops based on FEC statistics.
A: Too many errors to get… | column | LUM-TCFaultStatusWithNA | .1.3.6.1.4.1.8708.2.48.2.5.1.1.7 |
| ifOpticalFecSignalDegraded Signal degraded (SD).
Too many error corrected. If more errors are corrected
it might effect the client signal in a negative way. | column | LUM-TCFaultStatusWithNA | .1.3.6.1.4.1.8708.2.48.2.5.1.1.8 |
| ifOpticalFecSignalDegradeThreshold Threshold for signal degraded alarm,
based on BER value.
Predefined levels
rxBerLevel1 = 1E-12
rxBerLevel2 = 1E-13
rxBerLevel3 = 1E-15
… | column | LUM-TCBerLevelMTOSI | .1.3.6.1.4.1.8708.2.48.2.5.1.1.9 |