autoFTPCallMode

LENOVO-XCC-MIB · .1.3.6.1.4.1.19046.11.1.8.6.1

Object

scalar mandatory Enumeration
This field specifies the automated problem reporting mode. Automated problem reporting mode allows the XCC to automatically put
service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time,
only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event
can be sent for the same failed component.

Context

MIB
LENOVO-XCC-MIB
OID
.1.3.6.1.4.1.19046.11.1.8.6.1
Type
scalar
Access
readonly
Status
mandatory
Parent
autoFTPSetup
Siblings
3

Syntax

Enumeration

Values & Constraints

Enumerated Values
0disabled
1ftp
2tftp
3sftp

Related Objects

Sibling Objects