infoCacheStatus
LEFTHAND-NETWORKS-NSM-INFO-MIB ·
.1.3.6.1.4.1.9804.3.1.1.2.1.91.1.91
Object
column
Enumeration
The RAID controller cache status.
Context
- MIB
- LEFTHAND-NETWORKS-NSM-INFO-MIB
- OID
.1.3.6.1.4.1.9804.3.1.1.2.1.91.1.91- Type
- column
- Access
- readonly
- Status
- current
- Parent
- infoCacheEntry
- Table
- infoCacheTable
- Siblings
- 16
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | pass |
2 | fail |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| infoCacheIndex Index for the infoCacheTable table. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.1 |
| infoCacheName The RAID controller cach name. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.2 |
| infoCacheBpsVoltage The RAID controller BPS (Backup Power Source) voltage. | column | Volts SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.20 |
| infoCacheBpsTestOverdue The BPS (Backup Power Source) test due state. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.21 |
| infoCacheBpsState The BPS (Backup Power Source) state. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.22 |
| infoCacheBpsStatus The BPS (Backup Power Source) status. | column | Enumeration | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.23 |
| infoCacheModel The RAID controller cache model. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.3 |
| infoCacheSize The RAID controller cache size. | column | mB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.4 |
| infoCacheSerialNumber The RAID controller cache serial number. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.5 |
| infoCacheEnabled The BPS (Backup Power Source) write cache enabled state. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.50 |
| infoCacheMode The BPS (Backup Power Source) cache mode. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.51 |
| infoCacheHardwareVersion The RAID controller hardware version. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.6 |
| infoCacheFirmwareVersion The RAID controller firmware version. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.7 |
| infoCacheDriverVersion The RAID controller driver version. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.8 |
| infoCacheState The RAID controller cache state. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.90 |
| infoCacheRowStatus obsolete The table row status. Obsolete in SAN/iQ 8.5. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.9804.3.1.1.2.1.91.1.99 |