gs2310pPoeConfigurationPriority
LANCOM-GS2310P-MIB ·
.1.3.6.1.4.1.2356.800.3.2311.2.13.5.3.1.3
Object
column
r/w
Enumeration
The Priority represents the ports priority. There are three levels of power priority named Low, High and Critical. 0: Low, 1: High, 2: Critical, default: Low.
Context
- MIB
- LANCOM-GS2310P-MIB
- OID
.1.3.6.1.4.1.2356.800.3.2311.2.13.5.3.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- gs2310pPoeConfigurationEntry
- Table
- gs2310pPoeConfigurationTable
- Siblings
- 5
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | low |
1 | high |
2 | critical |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| gs2310pPoeConfigurationPort port, range : 1 - port number. | column | Integer32 | .1.3.6.1.4.1.2356.800.3.2311.2.13.5.3.1.1 |
| gs2310pPoeConfigurationPoEMode The PoE Mode represents the PoE operating mode for the port.
0: Disable,
1: Enable,
default: Enable. | column | Enumeration | .1.3.6.1.4.1.2356.800.3.2311.2.13.5.3.1.2 |
| gs2310pPoeConfigurationMaximumPower The Maximum Power value contains a numerical value that indicates the maximum
power in watts that can be delivered to a remote device.
default: 15.4[W],
max: 30[W]. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2311.2.13.5.3.1.4 |
| gs2310pPoeConfigurationDetection Configure PoE port capacitor detection.
0: No Detection(read only),
1: legacy,
2: 4-point,
3: 4-point-legacy,
4: 2-point,
5: 2-point-legacy,
default: 4-point. | column | Integer32 | .1.3.6.1.4.1.2356.800.3.2311.2.13.5.3.1.5 |
| gs2310pPoeConfigurationReset Reset the specific PoE port.
0: Disable,
1: Enable,
default: Disable. | column | Enumeration | .1.3.6.1.4.1.2356.800.3.2311.2.13.5.3.1.6 |