gs2310pIGMPSnoopingVLANQRI

LANCOM-GS2310P-MIB · .1.3.6.1.4.1.2356.800.3.2311.2.16.2.1.7

Object

column r/w Integer32
Query Response Interval. The Maximum Response Delay used to calculate
the Maximum Response Code inserted into the periodic General Queries. The
 allowed range is 0 to 31744 in tenths of seconds, default query response
  interval is 100 in tenths of seconds (10 seconds).   (-1: none)

Context

MIB
LANCOM-GS2310P-MIB
OID
.1.3.6.1.4.1.2356.800.3.2311.2.16.2.1.7
Type
column
Access
readwrite
Status
current
Parent
gs2310pIGMPSnoopingVLANEntry
Table
gs2310pIGMPSnoopingVLANTable
Siblings
8

Syntax

Integer32

Values & Constraints

Object Constraints
range: -1-31744