gs2328fACLACEStatusID
LANCOM-GS-2328F-MIB ·
.1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.3
Object
column
Integer32
ACE ID. range : 1 - 256.
Context
- MIB
- LANCOM-GS-2328F-MIB
- OID
.1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- gs2328fACLACEStatusEntry
- Table
- gs2328fACLACEStatusTable
- Siblings
- 11
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-256
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| gs2328fACLACEStatusIndex | column | Integer32 | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.1 |
| gs2328fACLACEStatusCPU Forward packet that matched the specific ACE to CPU. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.10 |
| gs2328fACLACEStatusCounter The counter indicates the number of times the ACE was hit by a frame. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.11 |
| gs2328fACLACEStatusConflict Indicates the hardware status of the specific ACE. The specific ACE is not applied to the hardware due to hardware limitations. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.12 |
| gs2328fACLACEStatusUser Indicates the ACL user.
S : Static.
IPMG : IP Management.
IPSG : IP Source Guard.
IPMC : IPMC.
ARPI : Arp Inspection.
UPnP : UPnP.
DHCP : DHCP. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.2 |
| gs2328fACLACEStatusIngressPort Indicates the ingress port of the ACE. Possible values are:
All: The ACE will match all ingress port.
Port: The ACE will match a specific ingress port. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.4 |
| gs2328fACLACEStatusFrameType Indicates the frame type of the ACE. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.5 |
| gs2328fACLACEStatusAction Indicates the forwarding action of the ACE. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.6 |
| gs2328fACLACEStatusRateLimiter Indicates the rate limiter number of the ACE. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.7 |
| gs2328fACLACEStatusPortCopy Indicates the port redirect operation of the ACE. Frames matching the ACE are redirected to the port number. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.8 |
| gs2328fACLACEStatusMirror Specify the mirror operation of this port. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2332.2.9.3.6.1.9 |