gs2326pPoeConfigurationReset
LANCOM-GS-2326P-MIB ·
.1.3.6.1.4.1.2356.800.3.2327.2.13.5.3.1.6
Object
column
r/w
Enumeration
Reset the specific PoE port. 0: Disable, 1: Enable, default: Disable.
Context
- MIB
- LANCOM-GS-2326P-MIB
- OID
.1.3.6.1.4.1.2356.800.3.2327.2.13.5.3.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- gs2326pPoeConfigurationEntry
- Table
- gs2326pPoeConfigurationTable
- Siblings
- 5
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | disable |
1 | enable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| gs2326pPoeConfigurationPort port, range : 1 - port number. | column | Integer32 | .1.3.6.1.4.1.2356.800.3.2327.2.13.5.3.1.1 |
| gs2326pPoeConfigurationPoEMode The PoE Mode represents the PoE operating mode for the port.
0: Disable,
1: Enable,
default: Enable. | column | Enumeration | .1.3.6.1.4.1.2356.800.3.2327.2.13.5.3.1.2 |
| gs2326pPoeConfigurationPriority The Priority represents the ports priority. There are three levels of power priority named Low, High and Critical.
0: Low,
1: High,
2: Critical,
default: Low. | column | Enumeration | .1.3.6.1.4.1.2356.800.3.2327.2.13.5.3.1.3 |
| gs2326pPoeConfigurationMaximumPower The Maximum Power value contains a numerical value that indicates the maximum
power in watts that can be delivered to a remote device.
default: 15.4[W],
max: 30[W]. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2356.800.3.2327.2.13.5.3.1.4 |
| gs2326pPoeConfigurationDetection Configure PoE port capacitor detection.
0: No Detection(read only),
1: legacy,
2: 4-point,
3: 4-point-legacy,
4: 2-point,
5: 2-point-legacy,
default: 4-point. | column | Integer32 | .1.3.6.1.4.1.2356.800.3.2327.2.13.5.3.1.5 |