trapObjects
KELVIN-pCOWeb-Chiller-MIB ·
.1.3.6.1.4.1.9839.2.1.100
Object
node
No description available.
Context
- MIB
- KELVIN-pCOWeb-Chiller-MIB
- OID
.1.3.6.1.4.1.9839.2.1.100- Type
- node
- Parent
- kelvin-pCOWebMIB-Chiller
- Siblings
- 3
- Children
- 86
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| digitalObjects | node | - | .1.3.6.1.4.1.9839.2.1.1 |
| analogObjects | node | - | .1.3.6.1.4.1.9839.2.1.2 |
| integerObjects | node | - | .1.3.6.1.4.1.9839.2.1.3 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| high-pressure-switch-1-alarm High pressure switch 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.1 |
| water-static-pressure-warning Water static pressure warning | notification | - | .1.3.6.1.4.1.9839.2.1.100.10 |
| flow-rate-alarm Flow rate alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.11 |
| overload-compressor1-circuit1-alarm Overload compressor 1 circuit 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.12 |
| overload-compressor2-circuit1-alarm Overload compressor 2 circuit 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.13 |
| remote-on-off Remote on-off | notification | - | .1.3.6.1.4.1.9839.2.1.100.130 |
| chiller-ON-OFF Chiller ON/OFF | notification | - | .1.3.6.1.4.1.9839.2.1.100.131 |
| overload-compressor3-circuit1-alarm Overload compressor 3 circuit 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.14 |
| alarm-disch-scw-1 Discharge screw compressor 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.148 |
| alarm-disch-scw-2 Discharge screw compressor 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.149 |
| overload-compressor1-circuit2-alarm Overload compressor 1 circuit 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.15 |
| alarm-probe-inlet Inlet probe alarm (broken or disconnected) | notification | - | .1.3.6.1.4.1.9839.2.1.100.150 |
| alarm-probe-amb Ambient probe alarm (broken or disconnected) | notification | - | .1.3.6.1.4.1.9839.2.1.100.151 |
| alarm-frigo-fl1 Flow switch alarm (cooling alarm) | notification | - | .1.3.6.1.4.1.9839.2.1.100.152 |
| alarm-idro-pump1 Pump 1 hydraulic alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.153 |
| alarm-idro-pump2 Pump 2 hydraulic alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.154 |
| alarm-idro-fl1 Flow switch alarm (hydraulic alarm) | notification | - | .1.3.6.1.4.1.9839.2.1.100.155 |
| alarm-warning-fl1 Flow switch alarm (warning alarm) | notification | - | .1.3.6.1.4.1.9839.2.1.100.156 |
| alarm-hi-water-temp High Temperature alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.157 |
| alarm-lo-water-temp Low Temperature alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.158 |
| alarm-ta-probe1 Antifreeze/evaporator probe 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.159 |
| overload-compressor2-circuit2-alarm Overload compressor 2 circuit 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.16 |
| alarm-hi-press High condensation pressure alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.160 |
| alarm-lo-press Low condensation pressure alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.161 |
| alarm-probe-evap-1 Antifreeze/evaporator probe 1 alarm (broken or disconnected) | notification | - | .1.3.6.1.4.1.9839.2.1.100.162 |
| alarm-probe-evap-2 Antifreeze/evaporator probe 2 alarm (broken or disconnected) | notification | - | .1.3.6.1.4.1.9839.2.1.100.163 |
| alarm-hi-press-1 High condensation pressure 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.164 |
| alarm-hi-press-2 High condensation pressure 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.165 |
| alarm-lo-press-1 Low condensation pressure 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.166 |
| alarm-lo-press-2 Low condensation pressure 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.167 |
| alarm-probe-tank Tank/Out probe alarm (broken or disconnected) | notification | - | .1.3.6.1.4.1.9839.2.1.100.168 |
| alarm-off-line-1 Chiller 1 offline | notification | - | .1.3.6.1.4.1.9839.2.1.100.169 |
| overload-compressor3-circuit2-alarm Overload compressor 3 circuit 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.17 |
| alarm-off-line-2 Chiller 2 offline | notification | - | .1.3.6.1.4.1.9839.2.1.100.170 |
| alarm-off-line-3 Chiller 3 offline | notification | - | .1.3.6.1.4.1.9839.2.1.100.171 |
| alarm-off-line-4 Chiller 4 offline | notification | - | .1.3.6.1.4.1.9839.2.1.100.172 |
| alarm-off-line-5 Chiller 5 offline | notification | - | .1.3.6.1.4.1.9839.2.1.100.173 |
| alarm-off-line-6 Chiller 6 offline | notification | - | .1.3.6.1.4.1.9839.2.1.100.174 |
| alarm-off-line-7 Chiller 7 offline | notification | - | .1.3.6.1.4.1.9839.2.1.100.175 |
| alarm-off-line-8 Chiller 8 offline | notification | - | .1.3.6.1.4.1.9839.2.1.100.176 |
| alarm-ta-probe2 Antifreeze/evaporator probe 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.177 |
| alarm-sms SMS alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.178 |
| alarm-modem Modem alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.179 |
| overload-fans-circuit1 Overload fans circuit 1 | notification | - | .1.3.6.1.4.1.9839.2.1.100.18 |
| alarm-sms-coda SMS coda alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.180 |
| alarm-probe-fc Freecooling probe alarm (broken or disconnected) | notification | - | .1.3.6.1.4.1.9839.2.1.100.181 |
| alarm-maint-pw1 Maintenance pump 1 alarm) | notification | - | .1.3.6.1.4.1.9839.2.1.100.182 |
| alarm-maint-pw2 Maintenance pump 2 alarm) | notification | - | .1.3.6.1.4.1.9839.2.1.100.183 |
| alarm-hi-temp-rid High temperature alarm (redundance) | notification | - | .1.3.6.1.4.1.9839.2.1.100.184 |
| alarm-q-fc-sep DryCooler breaker switch alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.185 |
| alarm-p-wat2 Water pressure 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.186 |
| alarm-p-wat1 Water pressure 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.187 |
| alarm-foult-flow-p1 Pump 1 flow alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.188 |
| alarm-foult-flow-p2 Pump 2 flow alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.189 |
| overload-fans-circuit2 Overload fans circuit 2 | notification | - | .1.3.6.1.4.1.9839.2.1.100.19 |
| alarm-foult-fl1-p1 Pump 1 flow-switch alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.190 |
| alarm-foult-fl1-p2 Pump 2 flow-switch alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.191 |
| alarm-warning-le Water level warning | notification | - | .1.3.6.1.4.1.9839.2.1.100.192 |
| alarm-frigo-fl-C Flow switch condensation alarm (cooling alarm) | notification | - | .1.3.6.1.4.1.9839.2.1.100.193 |
| alarm-idro-pump-c-1 Pump 1 condensation hydraulic alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.194 |
| alarm-idro-pump-c-2 Pump 2 condensation hydraulic alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.195 |
| alarm-idro-fl-C Flow switch condensation alarm (hydraulic alarm) | notification | - | .1.3.6.1.4.1.9839.2.1.100.196 |
| alarm-warning-fl-C Flow switch condensation alarm (warning alarm) | notification | - | .1.3.6.1.4.1.9839.2.1.100.197 |
| alarm-foul-fl-C-p1 Pump 1 condensation flow-switch alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.198 |
| alarm-foul-fl-C-p2 Pump 2 condensation flow-switch alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.199 |
| high-pressure-switch-2-alarm High pressure switch 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.2 |
| overload-fan1-circuit1-alarm Overload fan 1 circuit 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.20 |
| overload-fan2-circuit1-alarm Overload fan 2 circuit 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.21 |
| overload-fan3-circuit1-alarm Overload fan 3 circuit 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.22 |
| overload-fan4-circuit1-alarm Overload fan 4 circuit 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.23 |
| overload-fan1-circuit-2-alarm Overload fan 1 circuit 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.24 |
| overload-fan2-circuit2-alarm Overload fan 2 circuit 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.25 |
| overload-fan3-circuit2-alarm Overload fan 3 circuit 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.26 |
| overload-fan4-circuit2-alarm Overload fan 4 circuit 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.27 |
| overload-pump1-alarm Overload pump 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.28 |
| overload-pump2-alarm Overload pump 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.29 |
| low-pressure-switch-1-alarm Low pressure switch 1 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.3 |
| wrong-phase-rotation-alarm Wrong phase rotation alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.30 |
| back-Door-open-alarm Back Door open alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.31 |
| low-pressure-switch-2-alarm Low pressure switch 2 alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.4 |
| water-level-alarm Water level alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.6 |
| alarm-idrofrigo-pump-c-1 Condensation pump 1 breaker switch alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.75 |
| alarm-idrofrigo-pump-c-2 Condensation pump 2 breaker switch alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.76 |
| flow-switch-alarm Flow switch alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.8 |
| alarm-idrofrigo-fl-C Condensation flow switch alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.80 |
| water-static-pressure-alarm Water static pressure alarm | notification | - | .1.3.6.1.4.1.9839.2.1.100.9 |