jnxPsuTemperatureInflow
JUNIPER-POWER-SUPPLY-UNIT-MIB ·
.1.3.6.1.4.1.2636.3.58.1.2.1.10
Object
scalar
Integer32
Average inflow temperature calculated from all the available input sensors on the master RE.
Context
- MIB
- JUNIPER-POWER-SUPPLY-UNIT-MIB
- OID
.1.3.6.1.4.1.2636.3.58.1.2.1.10- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- jnxPsuScalars
- Siblings
- 12
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| jnxPsuAvailableDeviceCount Gives the number of PSU units available online in the System. | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.1 |
| jnxPsuTemperatureOutflow Average outflow temperature calculated from all
the available output sensors on the master RE. | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.11 |
| jnxPsuTemperatureInflowSamples The number of samples being taken while calculating
jnxPsuTemperatureInflow. | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.12 |
| jnxPsuTemperatureOutflowSamples The number of samples being taken while calculating
jnxPsuTemperatureOutflow. | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.13 |
| jnxPsuAvailableAveragePowerSupply Gives the total average power that the System can supply from the
available online units in Watts. | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.2 |
| jnxPsuAvailableMaxPowerSupply Gives the total maximum power that the System can supply from the
available online units in Watts. | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.3 |
| jnxPsuRedundancy PSU power redundancy configuration. | scalar | Enumeration | .1.3.6.1.4.1.2636.3.58.1.2.1.4 |
| jnxPsuChassisPowerReserved Power reserved for Chassis in Watts. | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.5 |
| jnxPsuChassisPowerAllocated Total power allocated for chassis and all the FPCs in Watts. | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.6 |
| jnxPsuRedundantPowerAvailable Power(in Watts) that is still available for allocation
even while supporting redundancy with the present usage. | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.7 |
| jnxPsuTotalPowerAvailable Power(in Watts) which could be made available for further
allocation without supporting any redundancy with the present usage. | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.8 |
| jnxPsuChassisPowerConsumed Total power consumed by the entire system rounded to the nearest integer.
This is calculated using the PowerFactor, Current and Voltage values
of each PSU that is online and conn… | scalar | Integer32 | .1.3.6.1.4.1.2636.3.58.1.2.1.9 |