jnxDomCurrentModuleVoltageHighAlarmThreshold
JUNIPER-DOM-MIB ·
.1.3.6.1.4.1.2636.3.60.1.1.1.1.26
Object
Module voltage high alarm threshold.
Context
- MIB
- JUNIPER-DOM-MIB
- OID
.1.3.6.1.4.1.2636.3.60.1.1.1.1.26- Type
- column
- Access
- readonly
- Status
- current
- Units
- 0.001 V
- Parent
- jnxDomCurrentEntry
- Table
- jnxDomCurrentTable
- Siblings
- 38
Syntax
0.001 V SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| jnxDomCurrentAlarms This object identifies all the active DOM alarms
on a SFF physical interface on this router. | column | JnxDomAlarmId | .1.3.6.1.4.1.2636.3.60.1.1.1.1.1 |
| jnxDomCurrentRxLaserPowerLowAlarmThreshold Receiver laser power low alarm threshold. | column | 0.01 dbm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.10 |
| jnxDomCurrentRxLaserPowerHighWarningThreshold Receiver laser power high warning threshold. | column | 0.01 dbm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.11 |
| jnxDomCurrentRxLaserPowerLowWarningThreshold Receiver laser power low warning threshold. | column | 0.01 dbm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.12 |
| jnxDomCurrentTxLaserBiasCurrentHighAlarmThreshold Transmitter laser bias current high alarm threshold. | column | 0.001 mA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.13 |
| jnxDomCurrentTxLaserBiasCurrentLowAlarmThreshold Transmitter laser bias current low alarm threshold. | column | 0.001 mA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.14 |
| jnxDomCurrentTxLaserBiasCurrentHighWarningThreshold Transmitter laser bias current high warning threshold. | column | 0.001 mA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.15 |
| jnxDomCurrentTxLaserBiasCurrentLowWarningThreshold Transmitter laser bias current low warning threshold. | column | 0.001 mA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.16 |
| jnxDomCurrentTxLaserOutputPowerHighAlarmThreshold Transmitter laser power high alarm threshold. | column | 0.01 dbm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.17 |
| jnxDomCurrentTxLaserOutputPowerLowAlarmThreshold Transmitter laser power low alarm threshold. | column | 0.01 dbm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.18 |
| jnxDomCurrentTxLaserOutputPowerHighWarningThreshold Transmitter laser power high warning threshold. | column | 0.01 dbm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.19 |
| jnxDomCurrentAlarmDate The system date and time when the management subsystem learned
of the current alarm event. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.2636.3.60.1.1.1.1.2 |
| jnxDomCurrentTxLaserOutputPowerLowWarningThreshold Transmitter laser power low warning threshold. | column | 0.01 dbm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.20 |
| jnxDomCurrentModuleTemperatureHighAlarmThreshold Module temperature high alarm threshold. | column | Celsius (degrees C) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.21 |
| jnxDomCurrentModuleTemperatureLowAlarmThreshold Module temperature low alarm threshold. | column | Celsius (degrees C) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.22 |
| jnxDomCurrentModuleTemperatureHighWarningThreshold Module temperature high warning threshold. | column | Celsius (degrees C) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.23 |
| jnxDomCurrentModuleTemperatureLowWarningThreshold Module temperature low warning threshold. | column | Celsius (degrees C) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.24 |
| jnxDomCurrentModuleVoltage Module voltage. | column | 0.001 V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.25 |
| jnxDomCurrentModuleVoltageLowAlarmThreshold Module voltage low alarm threshold. | column | 0.001 V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.27 |
| jnxDomCurrentModuleVoltageHighWarningThreshold Module voltage high warning threshold. | column | 0.001 V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.28 |
| jnxDomCurrentModuleVoltageLowWarningThreshold Module voltage low warning threshold. | column | 0.001 V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.29 |
| jnxDomLastAlarms This object identifies a copy of jnxDomCurrentAlarms
before last set or clear. | column | JnxDomAlarmId | .1.3.6.1.4.1.2636.3.60.1.1.1.1.3 |
| jnxDomCurrentModuleLaneCount Number of Lanes (Lasers) in this module | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.30 |
| jnxDomCurrentModuleMaxPower Worst case maximum power consumption | column | 0.25 W SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.31 |
| jnxDomCurrentModuleWavelengthChanNumber Wavelength Channel Number | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.32 |
| jnxDomCurrentModuleWavelengthSetpoint Operating Wavelength of the laser | column | 0.01 nm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.33 |
| jnxDomCurrentModuleFreqError Error between the target center frequency and the
actual current center frequency | column | 0.1 GHz SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.34 |
| jnxDomCurrentModuleWavelengthError Error between the target wavelength and the
actual wavelength at which the laser is operating | column | 0.1 nm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.35 |
| jnxDomCurrentLaserTemperatureHighAlarmThreshold Laser Temperature High Alarm Threshold | column | 1/256.0 Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.36 |
| jnxDomCurrentLaserTemperatureLowAlarmThreshold Laser Temperature Low Alarm Threshold | column | 1/256.0 Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.37 |
| jnxDomCurrentLaserTemperatureHighWarningThreshold Laser Temperature High Warning Threshold | column | 1/256.0 Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.38 |
| jnxDomCurrentLaserTemperatureLowWarningThreshold Laser Temperature Low Warning Threshold | column | 1/256.0 Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.39 |
| jnxDomCurrentWarnings This object identifies all the active DOM warnings
on a SFF physical interface on this router. | column | JnxDomWarningId | .1.3.6.1.4.1.2636.3.60.1.1.1.1.4 |
| jnxDomCurrentRxLaserPower Receiver laser power. | column | 0.01 dbm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.5 |
| jnxDomCurrentTxLaserBiasCurrent Transmitter laser bias current. | column | 0.001 mA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.6 |
| jnxDomCurrentTxLaserOutputPower Transmitter laser output power. | column | 0.01 dbm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.7 |
| jnxDomCurrentModuleTemperature Module temperature. | column | Celsius (degrees C) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.8 |
| jnxDomCurrentRxLaserPowerHighAlarmThreshold Receiver laser power high alarm threshold. | column | 0.01 dbm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2636.3.60.1.1.1.1.9 |