isDeviceConfigHumidityCalibration
ISPRO-MIB ·
.1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.8
Object
column
mandatory
r/w
IsproEnuHumidityCalibration
The set value to get the correct temperature according to your reference temperature.
Context
- MIB
- ISPRO-MIB
- OID
.1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.8- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- isDeviceConfigHumidityEntry
- Table
- isDeviceConfigHumidityTable
- Siblings
- 12
Syntax
IsproEnuHumidityCalibration
- Source
- IsproEnuHumidityCalibration
- Base type
Enumeration
Values & Constraints
Type Values
1 | humidityIncrease0Point0 |
2 | humidityIncrease0Point5 |
3 | humidityIncrease1Point0 |
4 | humidityIncrease1Point5 |
5 | humidityIncrease2Point0 |
6 | humidityIncrease2Point5 |
7 | humidityIncrease3Point0 |
8 | humidityDecrease0Point5 |
9 | humidityDecrease1Point0 |
10 | humidityDecrease1Point5 |
11 | humidityDecrease2Point0 |
12 | humidityDecrease2Point5 |
13 | humidityDecrease3Point0 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| isDeviceConfigHumidityIndex mandatory The index to a humidity device entry. | column | Integer32 | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.1 |
| isDeviceConfigHumidityLowCriticalState mandatory Enable/disable the set point to trigger low critical alarm. | column | IsproEnuEnable | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.10 |
| isDeviceConfigHumidityHighWarningState mandatory Enable/disable the set point to trigger high warning alarm. | column | IsproEnuEnable | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.11 |
| isDeviceConfigHumidityHighCriticalState mandatory Enable/disable the set point to trigger high critical alarm. | column | IsproEnuEnable | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.12 |
| isDeviceConfigHumidityEventDO mandatory Set the trigger action of humidity events. If event asserted,
this will invert the digital output #1 or #2. | column | IsproEnuDO | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.13 |
| isDeviceConfigHumidityName mandatory The humidity sensor name. | column | OctetString | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.2 |
| isDeviceConfigHumidityLowWarning mandatory The set point to trigger low warning alarm. the unit is 0.01 %. | column | Integer32 | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.3 |
| isDeviceConfigHumidityLowCritical mandatory The threshold to trigger low critical alarm. the unit is 0.01 %. | column | Integer32 | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.4 |
| isDeviceConfigHumidityHighWarning mandatory The threshold to trigger high warning alarm. the unit is 0.01 %. | column | Integer32 | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.5 |
| isDeviceConfigHumidityHighCritical mandatory The threshold to trigger high critical alarm. the unit is 0.01 %. | column | Integer32 | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.6 |
| isDeviceConfigHumidityHysteresis mandatory The set value to prevent too many alarms when Humidity
is hovering around the set threshold. The unit is 0.01 | column | Integer32 | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.7 |
| isDeviceConfigHumidityLowWarningState mandatory Enable/disable the set point to trigger low warning alarm. | column | IsproEnuEnable | .1.3.6.1.4.1.19011.1.3.2.1.3.2.3.1.9 |