cmmSysOutputVoltageUnderResume
IPI-CMM-CHASSIS-MIB ·
.1.3.6.1.4.1.36673.100.1.2.6.1.58
Object
column
0.01 V Integer32
Output voltage under resume value of PSU. '-100001' indicates unavailable
Context
- MIB
- IPI-CMM-CHASSIS-MIB
- OID
.1.3.6.1.4.1.36673.100.1.2.6.1.58- Type
- column
- Access
- readonly
- Status
- current
- Units
- 0.01 V
- Parent
- cmmSysPowerSupplyEntry
- Table
- cmmSysPowerSupplyTable
- Siblings
- 92
Syntax
0.01 V Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cmmSysPSUIndex The unique index of the power supply. | column | Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.1 |
| cmmSysOutputCurrent Output Current of Power supply.
'-100001' indicates unavailable.
'-100002' indicates not-applicable. | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.10 |
| cmmSysPSTemperature1 Temperature of Power supply sensor 1.
'-100001' indicates unavailable.
'-100002' indicates not-applicable. | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.11 |
| cmmSysPSTemperature2 Temperature of Power supply sensor 2.
'-100001' indicates unavailable.
'-100002' indicates not-applicable. | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.12 |
| cmmSysPSFan1Rpm Fan1 rpm of Power supply.
'-100001' indicates unavailable
'-100002' indicates not-applicable. | column | Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.13 |
| cmmSysPSFan2Rpm Fan2 rpm of Power supply.
'-100001' indicates unavailable
'-100002' indicates not-applicable. | column | Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.14 |
| cmmSysPS12VPg Status of Output Power | column | Enumeration | .1.3.6.1.4.1.36673.100.1.2.6.1.15 |
| cmmSysPSAcCritical Status of Input Power | column | Enumeration | .1.3.6.1.4.1.36673.100.1.2.6.1.16 |
| cmmSysPSParamsSupport Bitmap of supported paramaters of PSU Unit.
0 - not supported (values only for information)
1 - supported (values can be used for monitoring). | column | Bits | .1.3.6.1.4.1.36673.100.1.2.6.1.17 |
| cmmSysPSCapacity Output Power of Power supply.
'-100001' indicates unavailable.
'-100002' indicates not-applicable. | column | W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.18 |
| cmmSysPSConsumptionAlertThresholdMin Value represents alert min threshold of PSU output power.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.19 |
| cmmSysPowerSupplyOperStatus The status of the power supply. | column | Enumeration | .1.3.6.1.4.1.36673.100.1.2.6.1.2 |
| cmmSysPSConsumptionAlertThresholdMax Value represents alert max threshold of PSU output power.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.20 |
| cmmSysInputPowerAlertThresholdMin Value represents alert min threshold of PSU input power.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.21 |
| cmmSysInputPowerAlertThresholdMax Value represents alert max threshold of PSU input power.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.22 |
| cmmSysInputVoltageAlertThresholdMin Value represents alert min threshold of PSU input voltage.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.23 |
| cmmSysInputVoltageAlertThresholdMax Value represents alert max threshold of PSU input voltage.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.24 |
| cmmSysOutputVoltageAlertThresholdMin Value represents alert min threshold of PSU output voltage.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.25 |
| cmmSysOutputVoltageAlertThresholdMax Value represents alert max threshold of PSU output voltage.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.26 |
| cmmSysInputCurrentAlertThresholdMin Value represents alert min threshold of PSU input current.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.27 |
| cmmSysInputCurrentAlertThresholdMax Value represents alert max threshold of PSU input current.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.28 |
| cmmSysOutputCurrentAlertThresholdMin Value represents alert min threshold of PSU output current.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.29 |
| cmmSysPowerSupplyType The type of the power supply. | column | Enumeration | .1.3.6.1.4.1.36673.100.1.2.6.1.3 |
| cmmSysOutputCurrentAlertThresholdMax Value represents alert max threshold of PSU output current.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.30 |
| cmmSysPSTemperature1AlertThresholdMin Value represents alert min threshold of PSU sensor temperature1.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.31 |
| cmmSysPSTemperature1AlertThresholdMax Value represents alert max threshold of PSU sensor temperature1.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.32 |
| cmmSysPSTemperature2AlertThresholdMin Value represents alert min threshold of PSU sensor temperature2.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.33 |
| cmmSysPSTemperature2AlertThresholdMax Value represents alert max threshold of PSU sensor temperature2.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.34 |
| cmmSysPSConsumptionCriticalThresholdMin Value represents min critical threshold of PSU output power.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.35 |
| cmmSysPSConsumptionCriticalThresholdMax Value represents max critical threshold of PSU output power.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.36 |
| cmmSysInputPowerCriticalThresholdMin Value represents min critical threshold of PSU input power.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.37 |
| cmmSysInputPowerCriticalThresholdMax Value represents max critical threshold of PSU input power.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.38 |
| cmmSysInputVoltageCriticalThresholdMin Value represents min critical threshold of PSU input voltage.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.39 |
| cmmSysHotSwapStat Power status for HOT SWAP. | column | Enumeration | .1.3.6.1.4.1.36673.100.1.2.6.1.4 |
| cmmSysInputVoltageCriticalThresholdMax Value represents max critical threshold of PSU input voltage.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.40 |
| cmmSysOutputVoltageCriticalThresholdMin Value represents min critical threshold of PSU output voltage.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.41 |
| cmmSysOutputVoltageCriticalThresholdMax Value represents max critical threshold of PSU output voltage.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.42 |
| cmmSysInputCurrentCriticalThresholdMin Value represents min critical threshold of PSU input current.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.43 |
| cmmSysInputCurrentCriticalThresholdMax Value represents max critical threshold of PSU input current.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.44 |
| cmmSysOutputCurrentCriticalThresholdMin Value represents min critical threshold of PSU output current.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.45 |
| cmmSysOutputCurrentCriticalThresholdMax Value represents max critical threshold of PSU output current.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.46 |
| cmmSysPSTemperature1CriticalThresholdMin Value represents min critical threshold of PSU sensor temperature1.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.47 |
| cmmSysPSTemperature1CriticalThresholdMax Value represents max critical threshold of PSU sensor temperature1.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.48 |
| cmmSysPSTemperature2CriticalThresholdMin Value represents min critical threshold of PSU sensor temperature2.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.49 |
| cmmSysPSConsumption Output Power of Power supply.
'-100001' indicates unavailable.
'-100002' indicates not-applicable. | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.5 |
| cmmSysPSTemperature2CriticalThresholdMax Value represents max critical threshold of PSU sensor temperature2.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.50 |
| cmmSysInputVoltageOverShutdown Input voltage over shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.51 |
| cmmSysInputVoltageUnderShutdown Input voltage under shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.52 |
| cmmSysInputVoltageOverResume Input voltage over resume value of PSU.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.53 |
| cmmSysInputVoltageUnderResume Input voltage under resume value of PSU.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.54 |
| cmmSysOutputVoltageOverShutdown Output voltage over shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.55 |
| cmmSysOutputVoltageUnderShutdown Output voltage under shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.56 |
| cmmSysOutputVoltageOverResume Output voltage over resume value of PSU.
'-100001' indicates unavailable | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.57 |
| cmmSysInputPowerOverShutdown Input power over shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.59 |
| cmmSysInputPower Input Power of Power supply.
'-100001' indicates unavailable.
'-100002' indicates not-applicable. | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.6 |
| cmmSysInputPowerUnderShutdown Input power under shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.60 |
| cmmSysInputPowerOverResume Input power over resume value of PSU.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.61 |
| cmmSysInputPowerUnderResume Input power under resume value of PSU.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.62 |
| cmmSysOutputPowerOverShutdown Output power over shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.63 |
| cmmSysOutputPowerUnderShutdown Output power under shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.64 |
| cmmSysOutputPowerOverResume Output power over resume value of PSU.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.65 |
| cmmSysOutputPowerUnderResume Output power under resume value of PSU.
'-100001' indicates unavailable | column | 0.01 W Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.66 |
| cmmSysInputCurrentOverShutdown Input current over shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.67 |
| cmmSysInputCurrentUnderShutdown Input current under shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.68 |
| cmmSysInputCurrentOverResume Input current over resume value of PSU.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.69 |
| cmmSysInputVoltage Input Voltage of Power supply.
'-100001' indicates unavailable.
'-100002' indicates not-applicable. | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.7 |
| cmmSysInputCurrentUnderResume Input current under resume value of PSU.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.70 |
| cmmSysOutputCurrentOverShutdown Output current over shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.71 |
| cmmSysOutputCurrentUnderShutdown Output current under shutdown value of PSU.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.72 |
| cmmSysOutputCurrentOverResume Output current over resume value of PSU.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.73 |
| cmmSysOutputCurrentUnderResume Output current under resume value of PSU.
'-100001' indicates unavailable | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.74 |
| cmmSysPsuTemperature1OverShutdown PSU Temperature1 over shutdown value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.75 |
| cmmSysPsuTemperature1UnderShutdown PSU Temperature1 under shutdown value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.76 |
| cmmSysPsuTemperature1OverResume PSU Temperature1 over resume value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.77 |
| cmmSysPsuTemperature1UnderResume PSU Temperature1 under resume value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.78 |
| cmmSysPsuTemperature2OverShutdown PSU Temperature2 over shutdown value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.79 |
| cmmSysOutputVoltage Output Voltage of Power supply.
'-100001' indicates unavailable.
'-100002' indicates not-applicable. | column | 0.01 V Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.8 |
| cmmSysPsuTemperature2UnderShutdown PSU Temperature2 under shutdown value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.80 |
| cmmSysPsuTemperature2OverResume PSU Temperature2 over resume value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.81 |
| cmmSysPsuTemperature2UnderResume PSU Temperature2 under resume value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.82 |
| cmmSysPSTemperature3 Temperature of Power supply sensor 3.
'-100001' indicates unavailable.
'-100002' indicates not-applicable. | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.83 |
| cmmSysPSTemperature3AlertThresholdMin Value represents alert min threshold of PSU sensor temperature3.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.84 |
| cmmSysPSTemperature3AlertThresholdMax Value represents alert max threshold of PSU sensor temperature3.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.85 |
| cmmSysPSTemperature3CriticalThresholdMin Value represents min critical threshold of PSU sensor temperature3.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.86 |
| cmmSysPSTemperature3CriticalThresholdMax Value represents max critical threshold of PSU sensor temperature3.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.87 |
| cmmSysPsuTemperature3OverShutdown PSU Temperature3 over shutdown value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.88 |
| cmmSysPsuTemperature3UnderShutdown PSU Temperature3 under shutdown value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.89 |
| cmmSysInputCurrent Input Current of Power supply.
'-100001' indicates unavailable.
'-100002' indicates not-applicable. | column | 0.01 A Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.9 |
| cmmSysPsuTemperature3OverResume PSU Temperature3 over resume value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.90 |
| cmmSysPsuTemperature3UnderResume PSU Temperature3 under resume value.
'-100001' indicates unavailable | column | 0.01 C Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.91 |
| cmmSysPSFan3Rpm Fan3 rpm of Power supply.
'-100001' indicates unavailable
'-100002' indicates not-applicable. | column | Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.92 |
| cmmSysPSFan4Rpm Fan4 rpm of Power supply.
'-100001' indicates unavailable
'-100002' indicates not-applicable. | column | Integer32 | .1.3.6.1.4.1.36673.100.1.2.6.1.93 |